本文介绍了由 VxRail 实施的帐户和密码规则。VxRail 帐户命名建议,包括 vCenter ESXi 主机、VxRail Manager 和 Platform Services Controller (PSC) root 帐户,以及有关在 Dell VxRail 中使用的帐户密码最佳实践的一般建议。
更新:  五月 04, 2026 ID: 000158231

本文档重点介绍 Dell Technologies 企业和数据中心基础架构产品的最低代码版本、建议代码版本和最新代码版本。我们会仔细评估和监控代码部署数据,以确保产品版本符合我们严格的期望,为客户提供可靠的产品和解决方案。
更新:  五月 04, 2026 ID: 000205512

This article's intention is general awareness of VxRail Remote Support's procedure for determining when a storage drive should be replaced. Verification steps, information about log collection, and special circumstances are addressed.
更新:  五月 04, 2026 ID: 000158405

During initial cluster validation and host addition to an existing cluster, all affected nodes reported a NIC driver compliance error related to nic card.
更新:  五月 04, 2026 ID: 000431782

Intermittent delays in the Redfish Application Programming Interface (API) response may prevent the VxRail 8.0.361 cluster from displaying the host Product Serial Number Tag (PSNT) and "Management IPV4" fields in the physical view page. You can trigger a system cache refresh on the VxRail Manager to restore the physical view display.
更新:  五月 04, 2026 ID: 000356213

This procedure explains how to re-create a host management account.
更新:  五月 04, 2026 ID: 000401469

iDRAC is the backend of ISM which provides hardware monitoring functionality on the VxRail appliance. This article describes the required settings on iDRAC.
更新:  五月 04, 2026 ID: 000157690

This article provides PowerEdge server troubleshooting for No Power, No POST, No Boot and No Video issues. This includes blade, rack, and tower servers.
更新:  五月 04, 2026 ID: 000152161

This article outlines how to create a firmware baseline, view compliance reports, and apply updates in Dell OpenManage Enterprise.
更新:  五月 02, 2026 ID: 000144728

Event code: VXR500ENC19 This event code indicates "<Enclosure Management Module Name> has failed."
更新:  五月 01, 2026 ID: 000011668

Event code: VXR500AMP400 This event code indicates "The <sensor name> sensor has failed, and the last recorded value by the sensor was <current> A."
更新:  五月 01, 2026 ID: 000011666

Event code: VXR500ENC21 This event code indicates "<Enclosure elements name> has been removed."
更新:  五月 01, 2026 ID: 000011662

Event code: VXR500FAN0027 This event code indicates "The <sensor name> sensor has failed with a value of <fan speed> RPM."
更新:  五月 01, 2026 ID: 000011656

Event code: VXR500FAN0013 This event code indicates "<fan name> RPM is less than the lower critical threshold."
更新:  五月 01, 2026 ID: 000011658

Event VXR508SSD0002 triggers due to available spare being less than threshold value.
更新:  五月 01, 2026 ID: 000189228

Event VXR500STOR393 is triggered due to: Auto-configure stacking is not allowed.
更新:  五月 01, 2026 ID: 000189235

Attempting a copy-back operation on a non-unmap-capable drive triggers event code VXR500STOR375.
更新:  五月 01, 2026 ID: 000189234

本知识库文章简要讨论事件代码:VXR500FAN0016
更新:  五月 01, 2026 ID: 000011651

Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
更新:  五月 01, 2026 ID: 000185734

Event VXR500STOR374 triggers due to a non-Unmap-capable drive being used for a rebuild operation.
更新:  五月 01, 2026 ID: 000189233

Event code VXR508STOR373 is triggered due to a hot spare drive not supporting unmap when the virtual drive (VD) has it enabled.
更新:  五月 01, 2026 ID: 000189232

Event Code VXR508STOR372 triggers due to unmap being disabled or not supported on the controller.
更新:  五月 01, 2026 ID: 000189231

Event Code VXR508STOR371 indicates: Unable to use the physical drive arg1 because the drive selected is not unmap-capable for virtual drive configuration.
更新:  五月 01, 2026 ID: 000189229

Event code: VXR500FAN0020 This event code indicates "The <fan name> is non-functional."
更新:  四月 30, 2026 ID: 000011654

Event code: VXR500ENC23 This event code indicates "<enclosure name> - Issue with PHY <PHY data>."
更新:  四月 30, 2026 ID: 000011653

Event code: VXR500AMP405 This event code indicates "The <sensor name> sensor state has changed to a failed state with a value of <current> A."
更新:  四月 30, 2026 ID: 000011650

Event code: VXR500ENC3 This event code indicates "<Enclosure Name> is shutdown."
更新:  四月 30, 2026 ID: 000011649

Event code: VXR500FAN8503 This event code indicates "The Chassis was turned off because more than two internal fans stopped functioning."
更新:  四月 30, 2026 ID: 000011648

Event code: VXR500CBL0002 This event code indicates "Backplane <bay ID> signal cable disconnected."
更新:  四月 30, 2026 ID: 000011647

Event code: VXR500CBL0006 This event code indicates "Unsupported backplane <bay ID> configuration: Multiple RAID controllers cannot be connected to the same backplane."
更新:  四月 30, 2026 ID: 000011644