不确定更新 PowerEdge 系统中特定组件固件的过程?在此特定文章中了解应该怎么做。
已更新: 五月 23, 2026
ID: 000333712
利用“Reboot Required”筛选器并选择此筛选视图中的所有项目,会导致应用所有不合规固件组件的“make compliant”作业。当需要重新启动的组件部署到目标时,目标会被视为意外重新启动。仅当选择所有对象并使用“需要重新启动”筛选器时,才会出现此问题。所有其他过滤器均按设计正常工作。
已更新: 五月 22, 2026
ID: 000270340
New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
已更新: 五月 23, 2026
ID: 000326459
One-Time Boot option selected through iDRAC fails.
已更新: 五月 23, 2026
ID: 000322795
R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
已更新: 五月 23, 2026
ID: 000321587
Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
已更新: 五月 23, 2026
ID: 000315161
PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
已更新: 五月 23, 2026
ID: 000314166
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
已更新: 五月 23, 2026
ID: 000311902
Some Dell PowerEdge 16th Generation (16G) servers may exhibit a 0V reading for Central Processing Unit (CPU) Voltage Regulator sensors within the Integrated Dell Remote Access Controller 9 (iDRAC9) user interfaces.
已更新: 五月 23, 2026
ID: 000309893
Dell Micron 9550 E3.S NVMe Drive Activity-Led light turns off for a few seconds.
已更新: 五月 23, 2026
ID: 000309831
The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
已更新: 五月 23, 2026
ID: 000308774
第 15 代 PowerEdge 服务器在发生事件后无响应或停止PST0210响应。
已更新: 五月 22, 2026
ID: 000297851
During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
已更新: 五月 22, 2026
ID: 000278171
Performing a "yum update" check for Red Hat Enterprise Linux or SuSE Linux for Enterprise Servers updates may fail due to improper iDRAC RPM in the Dell YUM repository on linux.dell.com.
已更新: 五月 22, 2026
ID: 000262378
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
已更新: 五月 22, 2026
ID: 000256907
DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
已更新: 五月 22, 2026
ID: 000251806
CPUs can be perceived to be hot while server is idle.
已更新: 五月 22, 2026
ID: 000250878
Various Dell enterprise products behave unexpectedly if IPMI is intentionally disabled from communicating between the operating system and iDRAC. This can be done by disabling the "In-band Management Interface" setting in BIOS System Security settings.
已更新: 五月 22, 2026
ID: 000247770
All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
已更新: 五月 22, 2026
ID: 000246018
The HBA355i with Seagate 8 TB SAS hard drive fails to boot to Windows Server 2022 after a cold boot.
已更新: 五月 22, 2026
ID: 000245194
在 ESXi 8.0 U3 安装期间观察到系统停止响应或紫屏死机 (PSOD),
已更新: 五月 21, 2026
ID: 000241608
iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
已更新: 五月 21, 2026
ID: 000240336
The BIOS setting changes may not appear in iDRAC if configured using the F11 Boot Manager on Dell PowerEdge 16G and 17G platforms.
已更新: 五月 21, 2026
ID: 000238951
本文可帮助您在戴尔支持站点上找到并下载较旧版本的适用于 ESXI 的戴尔自定义 ISO。
已更新: 五月 21, 2026
ID: 000238184
这是 Dell OpenManage Enterprise 4.3.x 支持矩阵的最新版本。
已更新: 五月 21, 2026
ID: 000237971
The Dell SS540 SAS solid state drive is reported as not correctly functioning.
已更新: 五月 21, 2026
ID: 000237298
PowerEdge servers with Emulex Fiber Channel (FC) driver version 12.01.12 may fail driver installation under Windows Defender Application Control (WDAC) Enforced Mode on Windows Server.
已更新: 五月 21, 2026
ID: 000236792
PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
已更新: 五月 21, 2026
ID: 000236776
In some instances, the firmware update job may fail to initiate when performing a firmware update through available iDRAC interfaces.
已更新: 五月 21, 2026
ID: 000234480
This article provides a step-by-step guide on how to remove and install a cooling fan on a Dell system. These instructions are applicable to both standard and high-performance fans. The guide covers the removal and installation of the cooling fan assembly.
已更新: 五月 21, 2026
ID: 000234366