文章
輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元
顯示 30 個,共 310 個
顯示 310 個,共 310 個
本文详细介绍了在 PowerEdge 服务器上可能会出现的电源装置 (PSU) 问题的故障排除步骤。
已更新: 五月 11, 2026
ID: 000127944
了解如何在戴尔设备上使用 iDRAC9 和 iDRAC10 创建和导出 SupportAssist 收集。使用此分步指南解决技术问题。
已更新: 五月 11, 2026
ID: 000126308
PowerFlex Manager generates a 2-year default self-signed SSL certificate when it is deployed. You can replace this default SSL certificate by generating a CSR, having it signed by a trusted certificate authority and uploading the signed certificate to PowerFlex Manager. If you are not using a trusted certificate authority and must renew the default self-signed SSL certificate, then you can use the following instructions.
已更新: 五月 11, 2026
ID: 000191512
无法使用 PowerFlex Manager 更改节点操作系统密码,并显示错误 VXFM00685。在 PowerFlex ManagerUI 中为节点更改密码后,错误显示故障。
已更新: 五月 11, 2026
ID: 000226395
Disk devices attached or configured to SVM or SDS nodes are missing Serial Number information and are not listed in the /dev/disk/by-id directory.
已更新: 五月 11, 2026
ID: 000225903
无法使用 PFxM 升级交换机操作系统。
已更新: 五月 11, 2026
ID: 000222614
无法完成 PowerFlex MDS 系统的添加现有资源组向导。
已更新: 五月 11, 2026
ID: 000226694
我们收到了有关 ESXi 7.0 和 ESXi 8.0 的最新 VMware 修补程序版本自定义 ISO 的若干请求。新的 VMware 修补程序包括针对漏洞 CVE-2025-22224、CVE-2025-22225 和 CVE-2025-22226 的关键安全更新。VMSA-2025-0004 是 Broadcom 官方文章编号,通常用于向技术支持解释问题。
已更新: 五月 11, 2026
ID: 000291363
成功升级 PFMP 后,CloudLink (CL) 代理程序具有处于已连接和已断开连接状态的重复条目。
已更新: 五月 11, 2026
ID: 000319116
The 4.x PFxM UI is not loading because the PowerFlex Management Platform "PFMP" pod SDNAS gateway is not in a healthy state.
已更新: 五月 11, 2026
ID: 000220000
在 PFxM UI 中,有一个警报,指出未检索来自 MDM 的事件。
已更新: 五月 11, 2026
ID: 000221796
本知识库文章 (KBA) 概述了识别 PowerFlex 系列中版本的各种方法,仅包括 PowerFlex 解决方案和软件。
已更新: 五月 11, 2026
ID: 000222560
This article provides links to PowerFlex custom node technical documentation.
已更新: 五月 10, 2026
ID: 000213270
删除并重新添加资源组。
已更新: 五月 10, 2026
ID: 000237096
14‑gen Ready Nodes with ≥12 DIMMs can reboot, recorded in iDRAC as a BP1 power‑good voltage out‑of‑range error; signal noise on the backplane power cable creates loss alerts, risking data loss.
已更新: 五月 10, 2026
ID: 000035374
多个 PowerFlex 机架或设备存储节点报告电池性能下降。 iDRAC 显示错误“NVDIMM 电池未就绪,因为电池未充满电或发生瞬时电池事件”。
已更新: 五月 10, 2026
ID: 000218917
The "Software Serial ID" or "SWID" (usually starts wit ELMSIO....) is used to open Service Request for PowerFlex, and to start software renewal process. If the Software Serial ID is not available, you can also create cases using the "System Serial number" (usually starts with "ELMVX....)
已更新: 五月 10, 2026
ID: 000294556
The following procedure explains how to manually install an external SDC on a Debian-based server.
The steps in the procedure below are relevant for Debian/Ubuntu operating systems, including Proxmox Virtual Environment.
已更新: 五月 10, 2026
ID: 000462918
Dell has a Customer Replaceable Unit (CRU) program for many of our hardware systems. The CRU program allows customers to replace designated hardware components. For a list of the hardware components that are designated as CRU for a specific hardware system, go to the Dell Warranty and Maintenance Page.
已更新: 五月 10, 2026
ID: 000187496
PowerFlex Manager 报告与“STORAGE_POOL_UNBALANCED”、“NOT_ENOUGH_FAULT_UNITS_IN_SP”和“CONFIGURED_SPARE_CAPACITY_SMALLER_THAN_LARGEST_FAULT_UNIT”相关的错误警报。
已更新: 五月 09, 2026
ID: 000279687
This article explains how to use iDRAC Direct to manage your PowerEdge server.
已更新: 五月 09, 2026
ID: 000130077
不确定更新 PowerEdge 系统中特定组件固件的过程?在此特定文章中了解应该怎么做。
已更新: 五月 08, 2026
ID: 000333712
本文介绍如何将内部 HTTP 共享用于 4.x PowerFlex Manager 版本认证矩阵 (RCM)、Intelligent Catalog (IC) 和 ISO 上传。
已更新: 五月 08, 2026
ID: 000220681
This Article explains the details of an MDM cluster in a PowerFlex solution.
已更新: 五月 08, 2026
ID: 000249312
Slow, non‑SSD storage on the cluster VMs leads to etcd latency over one second, triggering repeated pod restarts, node NotReady states and loss of PowerFlex Management Platform (PFMP) UI access.
已更新: 五月 08, 2026
ID: 000222971
Offline upgrade of PowerFlex Manager
How to manually upgrade PowerFlex Manager without Secure Remote Services.
已更新: 五月 08, 2026
ID: 000183041
当生成警报的服务或 MDM 不再处于活动状态时,警报仍停留在 PowerFlex Manager UI 中。这会导致 UI 无法清除它们。
已更新: 五月 07, 2026
ID: 000220827
Details the graceful reboot of PowerFlex Management Platform (PFMP) VMs for version 4.X, including labeling, draining, and rebooting MVMs while keeping two nodes active and checking PostgreSQL health. In the scope of this procedure, MVM1 is the postgres Leader. It is drained and rebooted last.
已更新: 五月 07, 2026
ID: 000225550
PowerEdge 服务器中使用的 Samsung PM9D3a 和 PM9D5a NVMe SSD 缺乏对安全协议和数据模型 (SPDM) 的支持,导致 SPDM 相关功能失败。
已更新: 五月 07, 2026
ID: 000459691
网关或演示服务器可能会出现连接问题,并显示“端口超出范围”或“正在尝试重新连接”。
已更新: 五月 07, 2026
ID: 000198913