文章
輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元
顯示 30 個,共 122 個
顯示 122 個,共 122 個
本文档重点介绍 Dell Technologies 企业和数据中心基础架构产品的最低代码版本、建议代码版本和最新代码版本。我们会仔细评估和监控代码部署数据,以确保产品版本符合我们严格的期望,为客户提供可靠的产品和解决方案。
已更新: 五月 12, 2026
ID: 000205512
戴尔为我们的许多硬件系统提供了客户可更换部件 (CRU) 计划。CRU 计划允许客户更换指定的硬件组件。有关为特定硬件系统指定为 CRU 的硬件组件的列表,请转至戴尔保修和维护页面。
已更新: 五月 10, 2026
ID: 000187496
本文介绍如何查找打开戴尔存储和数据保护硬件产品的服务请求或支持案例所需的序列号、产品 ID 或产品序列号标签 (PSNT)。
已更新: 五月 12, 2026
ID: 000021638
Version Mismatch between the management server and directors causes all storage volumes to report their 'Operational Status' and 'Health State' as 'unknown'.
已更新: 五月 10, 2026
ID: 000188498
On element manager VPLEX HTML5 GUI, using the Storage View "Add/Remove Initiators" windows, the checkbox "show used initiators" does not work properly as it does not toggle visibility of initiators already bound to other storage views.
已更新: 五月 08, 2026
ID: 000184016
After Password Change of Active Directory Bind User for LDAPS on the active directory server the reconfiguration on VPlex clusters fails. AD user cannot authenticated on VPlex anymore.
已更新: 五月 08, 2026
ID: 000183742
在区域激活时,所有分区到 VPLEX 前端端口的 HBA 都将注销并丢失路径。ESX 主机可能会挂起,并且需要重新启动才能恢复。[Scott — 这是否仅影响 ESX 主机?摘要内容为“分区到 VPLEX 的所有 HBA”,我们是要将此限制为仅适用于 ESX 主机,还是重述为“主机可能会挂起,并且需要重新启动才能恢复”?]
已更新: 五月 07, 2026
ID: 000181952
本知识库文章是 Dell Technologies 制作的技术文档和视频的列表。
已更新: 五月 05, 2026
ID: 000182342
This article talks to the issue where the SSH access to the VPLEX management server fails. This article provides the workaround steps to resolve this issue.
已更新: 五月 05, 2026
ID: 000173992
This article discusses stale, or phantom arrays present after an array is removed from the VPLEX and the steps to take to remove the phantom array.
已更新: 五月 05, 2026
ID: 000173891
This article talks about how to mitigate DU when the LUN type is changed to thick on BE array, which was previously provisioned as thin on VPlex.
已更新: 五月 05, 2026
ID: 000172418
This article discusses the Back-End (BE) Path Management function that was added to GeoSynchrony 6.2 and later. It also discusses the handling of Back-End network congestion through its changed BE Path Management functionality.
已更新: 五月 05, 2026
ID: 000170881
The purpose of this article is to address Lightweight Directory Access Protocol (LDAP) login issues to the UNIX/Linux shell on an MMCS (VS6) or Management-Server (VS2). Upon successful LDAP login, the shown user is different than the user whose credentials were entered.
已更新: 五月 05, 2026
ID: 000170875
This article provides a description of the thin provisioning soft threshold dial-home and recommendations to resolve the warning.
已更新: 五月 05, 2026
ID: 000170715
This article talks about expanding a virtual-volume when protected by RecoverPoint.
已更新: 五月 05, 2026
ID: 000170477
This article talks to an issue where the ndu pre-check shows error in I/O aborts .
已更新: 五月 05, 2026
ID: 000168595
This article talks to an issue where SCSI UNMAP commands fail due to presenting distributed volumes on cross-connected or stretched hosts using different LUN IDs.
已更新: 五月 05, 2026
ID: 000168181
This article discusses an issue on the QLogic host bus adapters (HBAs) causing ESXi hosts to lose access to VPLEX volumes upon migration jobs commit.
已更新: 五月 05, 2026
ID: 000168170
This article talks to the issue where the Automated metadata backup fails due to "The active metadata device is not healthy." This article provides the remediation steps to resolve this error.
已更新: 五月 05, 2026
ID: 000167982
This article talks to what to do if a user is unable to reset a password for a User even though the Password follows all the rules and contains approved special characters.
已更新: 五月 04, 2026
ID: 000167720
This article talks to the issue where the distributed device hierarchy is missing an extent and how to resolve the missing extent.
已更新: 五月 04, 2026
ID: 000167451
The checksums of the package file do not match due to the parent directory folder owner:group value incorrect.
已更新: 五月 04, 2026
ID: 000167357
After a power outage, Management server reboot, or if the Management Console Service is restarted while the VPN is down, VPLEX reports "unreachable directors"
已更新: 五月 04, 2026
ID: 000167328
This article is to address the call homes for the following components: Uninterruptible Power Supply (UPS) (VS2/VS6), Standby-Power-Supply (SPS) (VS2), Power-Supply (psa/b) (VS2/VS6), and Battery Backup Unit (BBUs) (VS6), when any of these components are reported as being faulted. The necessary actions to be followed are covered in this article.
已更新: 五月 04, 2026
ID: 000167056
This article explains how to manage the I/O forwarding phase during a VPLEX Director NDU by using the --io-fwd-ask-for-confirmation and --io-fwd-timeout options. This allows users to configure the shortest timeout that still meets user requirements.
已更新: 五月 04, 2026
ID: 000158374
This article explains how to move one leg of logging volume from one array to another. This is done by detaching one of the existing legs and attaching the new leg from the new location.
已更新: 五月 04, 2026
ID: 000158372
This article details the steps to generate a SolVe Desktop procedure to Change IP addresses of a VPlex cluster.
已更新: 五月 04, 2026
ID: 000158332
This KB article shows how to view the current core CPU usage on a specific VPLEX director.
已更新: 五月 04, 2026
ID: 000158229
This article discusses creating a new meta volume when NO metadata volume exists, then moving the metadata that is in-memory to the newly created metadata volume.
已更新: 五月 04, 2026
ID: 000158227
This article talks on how to set up a customer monitor to track specific data.
已更新: 五月 04, 2026
ID: 000158030