文章
輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元
顯示 30 個,共 92 個
顯示 92 個,共 92 個
这是一个固件目录,其中包含基于戴尔自定义 ESXi 8.X 分支映像的选定 Dell VMware vSAN 就绪型节点的经过验证和认证的固件堆栈。
已更新: 五月 05, 2026
ID: 000225254
本文介绍如何在系统设置程序中查看和清除系统事件日志 (SEL)。
已更新: 五月 04, 2026
ID: 000226396
PowerEdge 16G BOSS N1; logs VLT0204 (BOSS CPLD voltage out of range) or VLT0205 on PowerEdge T160/R360/T360/R260 platforms running Complex Programmable Logic Device (CPLD) version 1.4.0.
PowerEdge R660 and R760 platforms running CPLD versions v1.2.6 will not log any voltage out of range warnings in the LC or SEL logs.
已更新: 五月 07, 2026
ID: 000382910
PowerEdge 服务器中使用的 Samsung PM9D3a 和 PM9D5a NVMe SSD 缺乏对安全协议和数据模型 (SPDM) 的支持,导致 SPDM 相关功能失败。
已更新: 五月 07, 2026
ID: 000459691
This article provides information about Dell Boot Optimized Storage Solution (BOSS) PCIe cards. It also provides instructions for installing Windows, Red Hat, SuSE, Ubuntu, and related Linux distributions onto these cards.
已更新: 五月 06, 2026
ID: 000177584
Domain Name System (DNS) resolving the local hostname may return the internal IP address of the USB Network Interface Card (NIC) passthrough device enabled by iDRAC Service Module (iSM). This can cause issues with internal network devices configured with 169.254.x.x nonroutable addresses. The metric of the USB NIC device should be manually set to a high number so that internal network devices take precedence.
已更新: 五月 06, 2026
ID: 000177295
This article outlines how to create a firmware baseline, view compliance reports, and apply updates in Dell OpenManage Enterprise.
已更新: 五月 05, 2026
ID: 000144728
本文提供了有关如何在 PowerEdge 服务器上禁用 C-State 和 C1E 的信息。
已更新: 五月 05, 2026
ID: 000135039
本文提供有关在 OMSA、系统设置页面和 iDRAC 界面中识别硬盘属性的信息。
已更新: 五月 05, 2026
ID: 000129559
本文介绍如何在Dell PowerEdge服务器上恢复BIOS默认设置。此过程可能对其它戴尔产品有效。
已更新: 五月 05, 2026
ID: 000128677
本文介绍了 PowerEdge 服务器中风扇噪音的一些常见的可能原因以及故障处理方法。
它还与 100% 风扇速度有关。
已更新: 五月 04, 2026
ID: 000227912
本文提供了建议的步骤,以帮助对 Dell PowerEdge 服务器上的内存相关事件进行故障处理。
已更新: 五月 04, 2026
ID: 000304931
如果 LifeCycle Controller (LCC) 已启用,但在 POST 期间菜单中没有它,则您可能需要导入 iDRAC 许可证才能再次启用它。
已更新: 五月 04, 2026
ID: 000205309
本操作方法解释了这些命令,并显示了相同的输出结果,以便使用命令控制台检索您的服务编号。
它显示为系统序列号。
已更新: 五月 04, 2026
ID: 000203494
本文介绍如何查找 iDRAC 的当前 MAC 地址。
已更新: 五月 04, 2026
ID: 000226214
本文介绍如何更换 vSAN 配置中的缓存磁盘。
已更新: 五月 04, 2026
ID: 000120252
This article provides PowerEdge server troubleshooting for No Power, No POST, No Boot and No Video issues. This includes blade, rack, and tower servers.
已更新: 五月 04, 2026
ID: 000152161
This article explains how to update the BIOS version of a Dell PowerEdge Server using EFI file. The update can be done directly from the Unified Extensible Firmware Interface (UEFI) interface.
已更新: 五月 01, 2026
ID: 000142454
The Dell Nautilus Firmware Update Utility is flexible and simple to use as it contains all the latest, relevant firmware updates for hard drives in your Dell server.
已更新: 五月 01, 2026
ID: 000141811
This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
已更新: 四月 30, 2026
ID: 000136481
Several requests regarding custom ISOs for the latest VMware patch releases for ESXi 7.0 and ESXi 8.0 have been received. The new VMware patch includes critical security updates for vulnerabilities CVE-2025-22224, CVE-2025-22225, and CVE-2025-22226. VMSA-2025-0004 is the official Broadcom article number which is commonly use to explain the issue to Tech Support.
已更新: 四月 29, 2026
ID: 000291363
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
已更新: 四月 29, 2026
ID: 000333712
Dell iDRAC9 and iDRAC10 remediations are available for OpenSSL vulnerabilities that could be exploited by malicious users to compromise the affected system.
已更新: 四月 28, 2026
ID: 000452302
本文介绍了使用戴尔支持页面打开服务请求 (SR) 的过程。
为您的戴尔设备快速获取帮助。无需再等待等待。不再有技术难题。
戴尔可让您通过设备或我们的支持网站轻松解决问题、安排维修或获取支持。
已更新: 四月 19, 2026
ID: 000132371
This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
已更新: 四月 19, 2026
ID: 000127944
了解如何在戴尔设备上使用 iDRAC9 和 iDRAC10 创建和导出 SupportAssist 收集。使用此分步指南解决技术问题。
已更新: 四月 19, 2026
ID: 000126308
有关 Intel SA-00329 的 Dell EMC 服务器平台安全公告 — Intel® 处理器数据泄露公告 — CVE-2020-0548、CVE-2020-0549
已更新: 四月 19, 2026
ID: 000124140
当 CPU 工作负载在 CPU PowerMax 或附近出现峰值时,具有 iDRAC9 的 PowerEdge 服务器可能会报告 CPU x 温度高于临界阈值上限事件。
已更新: 四月 18, 2026
ID: 000123186
使用 DDR4 的 PowerEdge 服务器上可纠正和不可纠正的内存错误,以及对故障处理步骤的更改
已更新: 四月 17, 2026
ID: 000053203
本文介绍使用 iDRAC9 UI 收集 SupportAssist 日志时可能发生的情况。此操作可能会导致错误,或者可能会收集不完整的日志。
已更新: 四月 03, 2026
ID: 000211904