Gå til hovedindhold
  • Afgiv ordrer hurtigt og nemt
  • Se ordrer og spor status for din forsendelse
  • Opret og få adgang til en liste med dine produkter
  • Administrer dine Dell EMC-websteder, -produkter og -kontaktpersoner på produktniveau ved hjælp af Company Administration (Virksomhedsadministration).

Dell Chassis Management Controller Version 3.0 for Dell EMC PowerEdge VRTX User's Guide

Understanding Redundant CMC Environment

You can install a standby CMC that takes over if your active CMC stops functioning. The redundant CMC may be pre-installed or can be installed later. To make sure full redundancy or best performance, it is important that the CMC network is properly cabled.

Failovers can occur when you:

  • Run the RACADM cmcchangeover command. See the cmcchangeover command section in the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals.
  • Run the RACADM racreset command on the active CMC. See the racreset command section in the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals..
  • Reset the active CMC from web interface. See the Reset CMC option for Power Control Operations that is described in Executing Power Control Operations.
  • Remove the network cable from the active CMC.
  • Remove the active CMC from the chassis.
  • Initiate a CMC firmware flash on the active CMC.
  • Have an active CMC that is no longer functional.
    NOTE In the event of a CMC failover, all iDRAC connections and all active CMC sessions are logged off. Users with logged-off sessions must reconnect to the new active CMC.

Bedøm indholdet

Nøjagtig
Nyttig
Nemt at forstå
Var denne artikel nyttig?
0/3000 characters
  Angiv vurderinger (1-5 stjerner).
  Angiv vurderinger (1-5 stjerner).
  Angiv vurderinger (1-5 stjerner).
  Angiv, om artiklen var nyttig eller ej.
  Kommentarer må ikke indeholde følgende specialtegn: <>()\