getflexaddr

Table 1. Details of getflexaddr. The following table provides the details of attribute:

Description

Enabled or disabled status is displayed for the entire chassis and fabric ID decoder. Use the command with -i option to display the MACs/WWN on a per-slot-basis 

The decoder values in the Type column indicate the protocols of the network cards:

  • 0— Unsupported

  • 1— ISCSI

  • 2— FCoE-FIP

  • 3— iSCSI/FCoE-FIP

To use this subcommand, you must have CMC Login User privilege.

  • NOTE: If FlexAddress is not activated on the chassis, the command displays server-assigned MAC/WWN addresses. If the slot is empty, the command leaves the server-assigned MAC/WWN addresses blank. If an external console controls the MAC/WWN addresses, the command displays an externally managed message.

Synopsis

racadm getflexaddr [-i <
                                                slotNum>]
                                             

Input

-i < slotNum > — Specifies the slot information to be displayed. < slotNum > must be from 1 to 4.

Table 2. Example .

Displays the current FlexAddress settings for all the slots and fabrics.

racadm getflexaddr

<
                                                Slot#> 
                                             
<
                                                Status>
                                             
<
                                                Server Presence>
                                             
1
Enabled
Present
2
Enabled
Present
3
Enabled
Not Present
4
Enabled
Not Present
<
                                                Fabric>
                                             
<
                                                Type>
                                             
<
                                                Status>
                                             
A
Gigabit Ethernet 
Enabled
B
None
Enabled
C
None
Enabled
Table 3. FlexAddress setting .

Displays the current FlexAddress setting for slot 4

racadm getflexaddr -i 4

Slot-4 server presence = Present

Slot-4 flexaddress enabled = 1

<
                                             Name>
                                          
<
                                             Type>
                                          
<
                                             Server-Assigned>
                                          
<
                                             Chassis-Assigned>
                                          
slot4-idrac 
Controller 
18:A9:9B:FD:C7:57
 F8:DB:88:3D:9F:A7(active) 
slot4-A
10 GbE KR
00:90:FA:51:36:54
 F8:DB:88:3D:9F:A8(active)
 
10 GbE KR/3
00:90:FA:51:36:55 
F8:DB:88:3D:9F:AA(active)
 
FCoE-WWN
10:00:00:90:FA:51:36:55 
20:01:F8:DB:88:3D:9F:AA(active)
 
10 GbE KR/3
00:90:FA:51:36:56
F8:DB:88:3D:A2:78(active)
  • NOTE: 10 GbE KR/3— The value 3 indicates the protocol type.