Table 1. Details of getpbinfo. The following table provides the details of getpbinfo attribute:

Description

Displays power budget status information.

To use this subcommand, you must have the CMC Login User privilege.

Synopsis

racadm getpbinfo 

Example

racadm getpbinfo
[Power Budget Status]
                                 System Input Power                              = 333 W
                                 Peak System Power                               = 403 W
                                 Peak System Power Timestamp                     = 15:38:01 06/14/2013
                                 Minimum System Power                            = 269 W
                                 Minimum System Power Timestamp                  = 19:12:27 09/22/2000
                                 Overall Power Health                            = OK
                                 Redundancy                                      = Yes
                                 System Input Power Cap                          = 5000 W
                                 Redundancy Policy                               = Power Supply Redundancy
                                 Dynamic PSU Engagement Enabled                  = No
                                 System Input Max Power Capacity                 = 2372 W
                                 Input Redundancy Reserve                        = 1182 W
                                 Input Power Allocated to Servers                = 327 W
                                 Input Power Allocated to Chassis Infrastructure = 427 W
                                 Total Input Power Available for Allocation      = 344 W
                                 Standby Input Power Capacity                    = 0 W
                                 Server Based Power Management Mode              = No
                                 Max Power Conservation Mode                     = No
                                 Server Performance Over Power Redundancy        = No
                              
                                 [Chassis Power Supply Status Table]
                                 <Name>          <Presence>      <Power State>   <Input Current> <Input Volts>   <Output Rated Power>
                                 PS1             Present         Online          1.3 A           115.5 V         1050 W
                                 PS2             Present         Online          1.6 A           116.0 V         1050 W
                                 PS3             Not Present     Slot Empty      N/A             N/A             N/A
                                 PS4             Not Present     Slot Empty      N/A             N/A             N/A
                              
[Server Module Power Allocation Table]
                                 <Slot#> <Server Name> <Power State>   <Allocation> <Priority>       <Blade Type>
                                 1       SLOT-01         OFF             0 W             1           PowerEdge M620
                                 2       SLOT-02         N/A             N/A             1           N/A
                                 3       SLOT-03         ON              327 W           1           PowerEdge M620
                                 4       SLOT-04         N/A             N/A             1           N/A
                              