Dell Storage Center SCv2000 and SCv2020 Storage System Deployment Guide

PDF

Back-End Connections for an SCv2000/SCv2020 Storage System Without Expansion Enclosures

When you deploy an SCv2000/SCv2020 storage system without expansion enclosures , you must interconnect the storage controllers using SAS cables. A single controller system should not connect a back-end SAS cable from port A to port B.

About this task

  • NOTE: The top storage controller is storage controller 1 and the bottom storage controller is storage controller 2.
Figure 1. SCv2000/SCv2020 Without Expansion EnclosuresInterconnecting the storage controllers.
  1. SCv2000/SCv2020 storage system
  2. Storage controller 1
  3. Storage controller 2
The following table describes the back-end SAS connections for an SCv2000/SCv2020 storage system without expansion enclosures .
Table 1. Storage System Without Expansion Enclosures
PathConnections
Chain 1: A Side (Orange)Storage controller 1: port A to storage controller 2: port B.
Chain 1: B Side (Blue)Storage controller 2: port A to the storage controller 1: port B.