Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

OpenManage Integration for VMware vCenter Version 4.0 Web Client User's Guide

Viewing hardware inventory information for chassis

You can view information about the hardware inventory within the selected chassis. To view the information in this page, ensure that you run an inventory job and export a CSV file with the component information.

Steps

  1. In the Home page, click vCenter.
  2. In the left pane, under OpenManage Integration, click Dell Chassis.
  3. In the left pane, select the corresponding chassis IP.
  4. Click the Monitor tab.
    To view the relevant component information, navigate through OMIVV:
    Table 1. Hardware inventory informationThe following table provides the information that is displayed for each of the chassis component.
    Hardware inventory: Component Navigation through OMIVV Information
    Fans

    Use either of the following methods:

    • In the Overview tab, click Fans.
    • In Monitor tab, expand the left pane, click Hardware Inventory, and then click Fans.

    Information about fans:

    • Name
    • Present
    • Power State
    • Reading
    • Warning Threshold
    • Critical Threshold
      • Minimum
      • Maximum
    Power supplies

    Use either of the following methods:

    • In the Overview tab, click Power Supplies.
    • In the Monitor tab, expand the left pane, click Hardware Inventory, and then click Power Supplies.

    Information about power supplies:

    • Name
    • Capacity
    • Present
    • Power state
    Temperature sensors

    Use either of the following methods:

    • In the Overview tab, click Temperature Sensors.
    • In the Monitor tab, expand the left pane, click Hardware Inventory, and then click Temperature Sensors.

    Information about temperature sensors:

    • Location
    • Reading
    • Warning threshold
      • Maximum
      • Minimum
    • Critical threshold
      • Maximum
      • Minimum
    NOTE: For PowerEdge M1000e chassis, information about the temperature sensors is displayed only for chassis. For other chassis, information about the temperature sensors is displayed for chassis and associated modular servers.
    I/O modules

    Use either of the following methods:

    • In Overview tab, click I/O Modules.
    • In Monitor tab, expand the left pane, click Hardware Inventory, and then click I/O Modules.

    Information about I/O modules:

    • Slot/Location
    • Present
    • Name
    • Fabric
    • Service Tag
    • Power Status
    To view additional information, select the corresponding I/O module and the following information is displayed:
    • Role
    • Firmware version
    • Hardware version
    • IP address
    • Subnet mask
    • Gateway
    • MAC address
    • DHCP enabled
    PCIe

    Use either of the following methods:

    • In the Overview tab, click PCIe.
    • In the Monitor tab, expand the left pane, click Hardware Inventory, and then click PCIe.

    Information about PCIe:

    • PCIe slot
      • Slot
      • Name
      • Power status
      • Fabric
    • Server slot
      • Name
      • Number
    To view additional information, select the corresponding PCIe and following information is displayed:
    • Slot type
    • Server mapping
    • Assignment status
    • Allocated slot power
    • PCI ID
    • Vendor ID
    NOTE: PCIe information is not applicable for M1000e chassis.
    iKVM

    Use either of the following methods:

    • In the Overview tab, click iKVM.
    • In the Monitor tab, expand the left pane, click Hardware Inventory, and then click iKVM.

    Information about iKVM:

    • iKVM Name
    • Present
    • Firmware version
    • Front Panel USB/Video enabled
    • Allow access to CMC CLI
    NOTE: You can view information about the iKVM only for PowerEdge M1000e Chassis
    NOTE: The iKVM tab is displayed only if the chassis contains iKVM module.

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"