Dell Chassis Management Controller Version 2.0 for PowerEdge FX2 and FX2s RACADM CLI Guide

PDF

getmodinfo

Description

Displays configuration and status information for all modules or a specified module (server, storage sled, switch, CMC, fan unit, blower, power supply unit, chassis, main-board, IO cable, and FPC cable) in the chassis.

To use this subcommand, you must have CMC Login User privilege.

  • NOTE: The Service Tag field is blank for modules that do not have Service Tags.
Synopsis
racadm getmodinfo [-m <
                                                module>] [-A]ra
                                             
Input
  • -m < module > — Specifies the module for which the configuration and status information is required. The default command (no options) displays information about all the major components in the chassis.
    < module > can be one of the following values:
    • server- n , where n = 1 to 4
    • server- nx , where n = 1 to 4; x = a to d
    • switch- n , where n = 1 or 2
    • pcie- n , where n = 1 to 8
    • CMC- n , where n = 1
    • fan- n , where n = 1 to 8
    • ps- n , where n = 1 to 2
    • chassis
    • main-board
    • io-cable
    • fpc cable
  • -A — Does not display the headers and labels in the output.
Example
  • racadm getmodinfo -m switch-1
  • < module> < presence> < pwrState> < health> < svcTag> Switch-1 Present ON OK CG09074
  • racadm getmodinfo
    <
                                                                            module>
                                                                         
    <
                                                                            presence>
                                                                         
    <
                                                                            pwrState>
                                                                         
    <
                                                                            health>
                                                                         
     <
                                                                            svcTag>
                                                                         
     <
                                                                            node Id>
                                                                         
    Chassis          
    Present 
     ON 
     OK 
    ST0MP19
     N/A
    Main-Board
    Present 
     ON 
    OK
    N/A
    N/A
    Storage-2	
    Present
    OFF
    Not OK
    6666666
    N/A
    Storage-3
    Present
    OFF
    Not OK
    6666666
    N/A
    Storage-4
    Present
    OFF
    OK
    6666666
    N/A
    Fan-1
    Present 
     ON 
    OK
    N/A
    N/A
    Fan-2
    Present 
     ON 
    Unknown
    N/A
    N/A
    Fan-3
    Present 
     ON 
    Unknown
    N/A
    N/A
    Fan-4
    Present 
     ON 
    Unknown
    N/A
    N/A
    Fan-5
    Present 
     ON 
    OK
    N/A
    N/A
    Fan-6
    Present 
     ON 
    Unknown
    N/A
    N/A
    Fan-7
    Present 
     ON 
    Unknown 
    N/A
    N/A
    Fan-8
    Present 
     ON 
    Unknown 
    N/A
    N/A
    PS-1
    Present 
    Online
    OK 
    N/A
    N/A
    PS-2
    Present 
    Online
    OK
    N/A
    N/A
    CMC
    Present 
    Primary
    OK
    N/A
    N/A
    Switch-1
    Present 
    ON
    OK
    0000000
    N/A
    Switch-2
    Present 
    ON
    OK
    N/A
    N/A
    Server-1
    Present 
    OFF
    OK
    H23H23Z
    H23H23Z
    Server-2a  
    Present 
    OFF
    OK
    JD3FRTW
    JD3FRTWa
    Server-2b
    Present 
    OFF
    OK
    JD3FRTW
    JD3FRTWb
    Server-2c   
    Present 
    OFF
    OK
    JD3FRTW
    JD3FRTWc
    Server-2d 
    Present 
    OFF
    OK
    JD3FRTW 
    JD3FRTWd
    Cable-IO
    Present
    ON
    OK
    STOMP11
    N/A
    Cable-CP
    Present
    ON
    OK
    STOMP11
    N/A

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"