vProxy: No contents return in download - HTTP status: "500 Internal Server Error" - Failed to initialize Backup Descriptor
摘要: The NetWorker VMware Protection (NVP) integration is configured with the vProxy appliance. During vProxy backups, some VMs fail to initialize the backup. vProxy is unable to download the VM's nvram file. Other VMs within the same group, ESX host, and/or datastore may backup successfully. ...
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
The NetWorker VMware Protection (NVP) integration is configured with the vProxy appliance. During vProxy backups, some VMs fail to initialize the backup. vProxy is unable to download the VM's nvram file. Other VMs within the same group, ESX host, and/or datastore may backup successfully.
YYYY/MM/DD HH:MM:SS TRACE: [156] Creating HTTP Get request to download contents of config file "[snap-67a44c9a-marvnx01_LUN73_CG02] LINUXVM05/LINUXVM05.nvram".
YYYY/MM/DD HH:MM:SS TRACE: [156] Starting download contents of config file "[snap-67a44c9a-marvnx01_LUN73_CG02] LINUXVM05/LINUXVM05.nvram".
YYYY/MM/DD HH:MM:SS ERROR: [156] No contents return in download of "[snap-67a44c9a-marvnx01_LUN73_CG02] LINUXVM05/LINUXVM05.nvram". HTTP status: "500 Internal Server Error"
YYYY/MM/DD HH:MM:SS ERROR: [156] Failed to download config file "[snap-67a44c9a-marvnx01_LUN73_CG02] LINUXVM05/LINUXVM05.nvram" using URL "https://vcenter01.testlab.com/folder/LINUXVM05/LINUXVM05.nvram?dcPath=Marlboro&dsName=snap-67a44c9a-marvnx01_LUN73_CG02".
YYYY/MM/DD HH:MM:SS INFO: [156] Failed HTTP request took 4.743977748s
YYYY/MM/DD HH:MM:SS TRACE: [156] HTTPRequest: &{GET https://vcenter01.testlab.com/folder/LINUXVM05/LINUXVM05.nvram?dcPath=Marlboro&dsName=snap-67a44c9a-marvnx01_LUN73_CG02 HTTP/1.1 1 1 map[Content-Type:[text/plain] Cookie:[vmware_soap_session=ab86aacaab8b1e992b72d0b40c1558c72eace96d]] <nil> 0 [] false vcenter01.testlab.com map[] map[] <nil> map[] <nil> <nil>}
YYYY/MM/DD HH:MM:SS TRACE: [156] Closing VM configuration file "/cambosddbku21/mar_boost_2/active/afeb4443-00000006-523895d9-5a3895d9-1baf5000-371b9256/vm-48941-config-file-1.cfg" ...
YYYY/MM/DD HH:MM:SS INFO: [156] Closed VM configuration file "/cambosddbku21/mar_boost_2/active/afeb4443-00000006-523895d9-5a3895d9-1baf5000-371b9256/vm-48941-config-file-1.cfg" ...
YYYY/MM/DD HH:MM:SS ERROR: [156] Failed to download VM config file "[snap-67a44c9a-marvnx01_LUN73_CG02] LINUXVM05/LINUXVM05.nvram" into saveset file "vm-48941-config-file-1.cfg".
YYYY/MM/DD HH:MM:SS ERROR: [156] Failed to Initialize Backup Descriptor.
原因
The HTTP error is coming from the ESXi host.
解决方案
Engage with VMware support to investigate the cause of the HTTP 500 (Internal Server Error)
Workaround:
Storage vMotion the VM to another datastore. The VM may be vMotioned back to its original datastore afterwards.
Workaround:
Storage vMotion the VM to another datastore. The VM may be vMotioned back to its original datastore afterwards.
受影响的产品
NetWorker产品
NetWorker文章属性
文章编号: 000032890
文章类型: Solution
上次修改时间: 02 11月 2023
版本: 3
从其他戴尔用户那里查找问题的答案