PowerPath Management Appliance (PPMA): Running rpowermt command returns "Segmentation fault"
Summary: Running rpowermt command returns "Segmentation fault" against PowerPath/VE (ESXi) hosts.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Running rpowermt command returns "Segmentation fault" against PowerPath/VE (ESXi) hosts.
Cause
This mostly is due to PPMA not able to communicate with the PowerPath/VE hosts and hence leads to this error.
Resolution
This issue has mostly been seen with PPMA 3.4 P01 (and onwards) with vSphere ESXi 8.x hosts.
This is due to the user (with which the vCenter is added) not having required privileges or the mandatory user "powerpath@vsphere.local" isn't used to add the vCenter to PPMA 3.4 P01.
This is due to the user (with which the vCenter is added) not having required privileges or the mandatory user "powerpath@vsphere.local" isn't used to add the vCenter to PPMA 3.4 P01.
Additional Information
See the Installation and Configuration Guide for more details.
Affected Products
VMware ESXi 8.xArticle Properties
Article Number: 000211601
Article Type: Solution
Last Modified: 26 Jun 2023
Version: 4