Data Domain: The Storage Processor has Failed - Coin Cell Battery failed (CMOS Battery)

Shrnutí: This article addresses the failure of the CMOS or system battery within a Data Domain. Alert Posted (EVT-ENVIRONMENT-00032) on Data Domain systems indicate the Storage Processor (SP) has failed. Additional information within the posted alert notification indicates the cause as "Coin cell battery failed." ...

Tento článek se vztahuje na Tento článek se nevztahuje na Tento článek není vázán na žádný konkrétní produkt. V tomto článku nejsou uvedeny všechny verze produktu.

Příznaky

Data Domain system posts an Alert notification to indicate the Storage Processor (SP) has failed.

"Additional Information" within the Posted alert states the cause is a failed coin-cell battery.
 
NOTE: This article is for the failed coin-cell (aka CMOS or System) battery. Other failures for the same Event ID (ENVIRONMENT-00032) are addressed in article Data Domain: Alert: The storage processor has failed.

Affected Systems:
  • All Data Domain Systems
  • All DDOS versions
Symptoms:  
  • Alert Notification:
Event Id: EVT-ENVIRONMENT-00032 Event Message: The storage processor has failed Object: Enclosure=1 Additional Information: Cause=Coin cell battery failed
  • BIOS log (within latest Auto-Support or Support Bundle)
Example: Coin-Cell entry shows <= 2.2 voltage (on legacy Data Domain systems)
Voltage CoinCell_Voltage | Lower Critical going low | Asserted | Reading 2.20
  • MESSAGES log (within latest Auto-Support or Support Bundle)
Multiple entries for SP failure, as below:
platmon: CRITICAL: The storage processor has failed. Enclosure=1 Cause="Coin cell battery failed"
  • On PowerEdge-based Systems (PowerProtect Data Domain), the failure is captured in iDRAC TSR Logs
The CMOS battery has failed

Unexpected system behavior may be encountered until the battery is replaced.

Příčina

If the battery voltage drops below the threshold, then the Alert (EVT-ENVIRONMENT-00032) is posted. The System Battery (a.k.a Coin cell, CMOS, or RTC) has a minimum voltage threshold to function as expected. Any reading below the given threshold is considered a battery failure, and it should be replaced immediately.

For legacy Data Domain systems, the voltage must be > 2.2 voltage.

For PowerProtect Data Domain systems, the voltage must be > 3v.

Řešení

For ALL Legacy Data Domain systems:
  • Dell Technologies does not stock system batteries.
  • A replacement SP must be dispatched.
For Current PowerProtect Data Domain systems:
  • PowerProtect (DD3300, DD6900, DD9400, DD9900, or newer models)
  • A replacement system battery must be dispatched.
Contact your contracted Support Provider or raise a new Service Request at Dell Support.

Další informace

For other 'Storage Processor has failed' cases, see article Data Domain: Alert: The storage processor has failed.

Dotčené produkty

Data Domain, PowerProtect Data Protection Appliance, Data Domain, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection Hardware