GDDR: GDDR992E Error 784 in GDDAVAL: Invalid global variable value passed received when running GDDR utility.

Shrnutí: The error 'GDDR992E Error 784 in GDDAVAL: Invalid global variable value passed was received when running a GDDR utility to delete DLM snapshot file system.

Tento článek se vztahuje na Tento článek se nevztahuje na Tento článek není vázán na žádný konkrétní produkt. V tomto článku nejsou uvedeny všechny verze produktu.

Příznaky

The customer has a GDDR Tape configuration and was performing a GDDR utility to delete DLm snapshot file system before running GDDR script GDD2P01A.

Although the utility was successful and completed with an RC=0 the following error messages were seen in the output:
22051-06:31:51 GDDR639I GDDR Completed DLMAUT Delete DLm Snapshot with rc 0  
GDDR992E Error 784 in GDDAVAL: Invalid global variable value passed (_20211010@15:21:11.776905_202109)
GDDR992E Arguments: GLOBAL.GDDR.RUND.GDDDLVSX.GDDDLVSX.RC U _20211010@15:21:11.776905_202109
GDDR992E Caller: GDDRGF0Z
22051-06:31:51 GDDR998E GDDR INTERNAL ERROR: CALL TECH SUPPORT - ID = GF0Z-99-40-132
22051-06:31:51 GDDR998E - xx = gddrval(varnamed,"U",lastdttm"_"currdate"@"currtime)

The issue occurred at GDDR 5.2 (GD52115) and Mainframe Enablers V8.5.

Příčina

The utility does not clear or reset the RUND variables when run in stand-alone fashion resulting in an ever-increasing length of the value for the RUND variables, ultimately leading to the invalid value message described in the GDDR992E error message.

Řešení

Workaround:

There is an immediate workaround to temporarily stop the GDDR992E error message from being issued. From the GDDR ISPF panels, use the Maintenance then the System option to delete the global variable GLOBAL.GDDR.RUND.GDDDLVSX.GDDDLVSX.RC. This prevents the GDDR992E error from occurring for approximately the next 20 executions of the DR test job.

Permanent Fix:
  • For GDDR V5.3, PTF GD53070 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.