Data Domain: Failed, Absent, Unknown, or Powered-off Disk
Summary: This article describes how to resolve the condition where a disk drive is in a failed, absent, or powered off state.
Αυτό το άρθρο ισχύει για
Αυτό το άρθρο δεν ισχύει για
Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν.
Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.
Symptoms
You may observe one or more of the following alerts or event codes indicating disk issues:
- Event Codes: STORAGE-00001, STORAGE-00002, PHYM-00001
- Alert Messages:
- Enclosure disk has failed and should be replaced
- Disk has a hardware fault and may need to be replaced
- Disk is absent and should be replaced
- Unable to access the disk; disk state is powered off
- A disk has failed, and the enclosure slot has been disabled
Affected Products:
- All Data Domain systems
- All Data Domain Operating System (DDOS) software releases
Cause
DDOS continuously monitors disk health and automatically fails a drive when critical I/O errors occur.
Alerts are generated when a disk is:
- Removed (absent)
- Dead or failed
- Powered off (manually or automatically by DDOS to prevent backend issues)
Resolution
Verify and confirm the failure:
- Verify the alerts on the system using DDMC, Data Domain System Manager (DDSM | Web-UI), or DD-CLI (ssh).
- DD-CLI #
alerts show current - DDSM > Alerts
- DD-CLI #
- Identify and confirm the current state of all drives in the system.
- DD-CLI #
disk show state| AND | #disk show hardware - DDSM >
Hardware > Storage > Disks - Single failed disks should be replaced immediately.
- Contact your support provider and raise a service request (SR) if one has not been raised automatically.
- If multiple disk drive alerts exist, contact your contracted support provider for assistance with the next steps.
- DD-CLI #
- Example: DD-CLI:
-
sysadmin@DD# disk show state Enclosure Disk 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 --------- ---------------------------------------------- 1 . . . 2 . . . . . . . . . . . . . . s 3 . . . . . . . . . . . . . . s 4 . . . . . . . . . . . . . . s 5 . . . . . F . . . . . . . . R 6 . . . . . . . . . . . . . . s --------- ----------------------------------------------> Here we see disk 5.6 (F)ailed > (R)econstructing to Spare disk 5.15 - Absent disks are marked as (A)
- Powered-off disks are marked as (P)
-
- For DD3300 disk issues, consider this KB:
Replace the failed disk:
- See relevant documented disk replacement procedures (Data Domain Documentation
- Tip: Best practice for replacing disk drives should include a one minute waiting period from the time a drive is removed until the new drive is inserted.
- For example, remove the failed disk, wait one minute and then insert the new disk.
- This allows the controller firmware to properly remove the old drive before the new drive is inserted, greatly reducing the possibility of a hotplug issue where the new drive is not properly recognized.
- For example, remove the failed disk, wait one minute and then insert the new disk.
- Tip: Best practice for replacing disk drives should include a one minute waiting period from the time a drive is removed until the new drive is inserted.
- Verify that the drive is in a SPARE state after replacement.
- From DD-CLI #
disk show state - DDSM >
Hardware > Storage > Disks - Example: DD-CLI:
sysadmin@DD# disk show state
Enclosure Disk
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
--------- ----------------------------------------------
1 . . .
2 . . . . . . . . . . . . . . s
3 . . . . . . . . . . . . . . s
4 . . . . . . . . . . . . . . s
5 . . . . . s . . . . . . . . .
6 . . . . . . . . . . . . . . s
--------- ----------------------------------------------> The newly installed disk becomes (s)pare and the reconstructed disk is now 'in-use'.
If the new drive reports as Unknown:
- Attempt a rescan of the drives. Run command #
disk rescan - Verify status of drive from DD-CLI #
disk show state - Clear the alert for unknown drive from DD-CLI #
alerts clear alert-id <alert-id>
If the new drive reports as failed after a drive replacement:
- Attempt to rescan the drive by rescanning the one or more drives. Run command #
disk rescan - Verify status of drive from DD-CLI #
disk show state - If the drive is still shown as failed (F), run this command from DD-CLI: #
disk unfail <encl.disc>
- For example: #
disk unfail 5.6
Clearing the drive alert after drive replacement:
- Clear the alert for the unknown drive from DD-CLI #
alerts clear alert-id <alert-id>
PowerProtect DD - Replacing Cache Tier Disk on DD6900/DD9400
Duration: 00:02:09 (hh:mm:ss)
Closed captions: None available
PowerProtect DD - Replacing Cache Tier Disk on DD9900
Duration: 00:02:13 (hh:mm:ss)
Closed captions: None available
Reference:
Data Domain - Disk State Description
Data Domain - How to Check Alerts on a Data Domain System
Replacement Procedures: Data Domain Documentation
Επηρεαζόμενα προϊόντα
Data DomainΙδιότητες άρθρου
Article Number: 000043773
Article Type: Solution
Τελευταία τροποποίηση: 12 Ιαν 2026
Version: 15
Βρείτε απαντήσεις στις ερωτήσεις σας από άλλους χρήστες της Dell
Υπηρεσίες υποστήριξης
Ελέγξτε αν η συσκευή σας καλύπτεται από τις Υπηρεσίες υποστήριξης.