PowerPath: PowerPath command powermt display stops responding in an AIX VIOS environment

Summary: This article explains the solution when the PowerPath command powermt display stops responding in an AIX VIOS environment.

Αυτό το άρθρο ισχύει για Αυτό το άρθρο δεν ισχύει για Αυτό το άρθρο δεν συνδέεται με κάποιο συγκεκριμένο προϊόν. Δεν προσδιορίζονται όλες οι εκδόσεις προϊόντων σε αυτό το άρθρο.

Symptoms

PowerPath commands such as powermt display, powermt config stop responding.
Command cfgmgr stops responding as well.
Attempt to use trace to follow a failing command fails.
dbx stops responding as well.

 

Cause

The incorrect read/write mode of a dependent semaphore in PowerPath 6.4 is the cause of this issue.
The mode of a dependent semaphore in the PowerPath 6.4 was set as write.

 

Resolution

The resolution to this issue is to upgrade PowerPath to version 7.0 or above.

 

 

Note: Disabling emcp_mond cannot be used as a workaround as it is also affected.

 

Additional Information

Environment:

Array: VMAX 250F

Host: IBM 9179-MHD
AIX: 6100-09-03-1415 (EOSL)
VIO: 2.2.6.21: NPIV Server, vSCSI Server
PowerPath: 6.4