NetWorker:儲存驗證資料庫時,啟動程式備份會失敗。Error: 「nsrauthcasm」以程式碼 1 結束 無法編碼引數
Summary: NetWorker:儲存驗證資料庫時,啟動程式備份會失敗。Error: 「nsrauthcasm」以程式碼 1 結束 無法編碼引數
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
NetWorker:儲存驗證資料庫時,啟動程式備份會失敗。Error: 「nsrauthcasm」以程式碼 1 結束「Can't encode arguments
Error from the Server db Backup action log-
Error from the Server db Backup action log-
save: Step (4 of 7) for PID-3224: Successfully connected to the target media device through the nsrmmd process on the host '<NetWorker server>' for the save set 'bootstrap'.
save: Step (5 of 7) for PID-3224: Reading the save sets and writing to the target device.
nsrauthcasm: The temporary file 'C:\Program Files\EMC NetWorker\nsr\authc-server\tomcat\data\authcdb_000001' for backup did not get generated correctly.
nsrauthcasm: XDR flush failed.
save: external ASM `nsrauthcasm' exited with code 1
:save: C:\Program Files\EMC NetWorker\nsr\authc-server\tomcat\data\authcdb.mv.db was not successfully saved
Can't encode arguments
save: save of 'bootstrap' to server '<NetWorker server>' failed.Cause
驗證資料庫檔案不相符。 在 NetWorker 19.8.x 上,C:\Program Files\EMC NetWorker\nsr\authc-server\tomcat\data\ 下的驗證資料是由兩個檔案所組成:authcdb.mv.db 和 authcdb.lock。 在這種情況下,驗證資料位置有 authcdb.h2.db 的複本,這是主動更新的副本,而非 authcdb.mv.db。
Resolution
重新建立驗證資料庫。在 Windows NetWorker 伺服器上,使用全新驗證檔案重新安裝 NetWorker 套件即可完成。
步驟:
1.從程式和功能卸載 NetWorker。
2.重新命名「C:\Program Files\EMC NetWorker\nsr\authc-server」
3.在現有檔案結構上重新安裝 NetWorker。將會建立新的 authc-server 目錄。
這不會對您現有的 NetWorker 組態或備份造成任何風險;但是,您需要重新建立 NetWorker 系統管理員密碼。如果您先前已設定其他 NetWorker 使用者或整合外部授權 (AD/LDAP),您將需要重新設定。
Article Properties
Article Number: 000217686
Article Type: Solution
Last Modified: 31 Oct 2023
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.