PowerFlex:如何使用命令列更新裝置路徑和清除 SDS 裝置錯誤
Summary: 即使在執行清理命令後,SDS 裝置錯誤也無法清除。以下是有關如何解決此問題的步驟。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
軟體定義儲存 (SDS) 錯誤回報如下:
4: Name: ScaleIO-3a5aeb6e Path: /dev/sdl Original-path: /dev/sde ID: 2a71c74700030003 Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error 13: Name: ScaleIO-3a5aeb77 Path: /dev/sdu Original-path: /dev/sdn ID: 2a71c7500003000c Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error
已嘗試命令:
scli --clear_sds_device_error --sds_id c948227100000004 --device_path /dev/sdp Successfully cleared SDS device sds: with ID c948227100000004, /dev/sdp
但是當檢查時,query_sds sds_id錯誤是相同的。
Cause
如果您查看 scli --query_sds --sds_id
4: Name: ScaleIO-3a5aeb6e Path: /dev/sdl Original-path: /dev/sde ID: 2a71c74700030003 Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error
路徑和原始路徑彼此不同。
Resolution
執行下列命令:
Scli --update_device_original_path --sds_id --device_id
例如:
scli --update_device_original_path --sds_id c948227000000003 --device_id 2a71c74700030003 scli --clear_sds_device_error --sds_id --device_id scli --clear_sds_device_error --sds_id c948227100000004 --device_id 2a71c74700030003
注意:使用 device_id 而非使用 device_path 作為裝置路徑在某些時候可能會有所不同,但上述命令將會修正相同的問題。
Affected Products
PowerFlex rack, ScaleIOArticle Properties
Article Number: 000027185
Article Type: Solution
Last Modified: 12 Nov 2025
Version: 8