Symptoms

軟體定義儲存 (SDS) 錯誤回報如下:  

4: Name: ScaleIO-3a5aeb6e  Path: /dev/sdl  Original-path: /dev/sde  ID: 2a71c74700030003
                Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error
 13: Name: ScaleIO-3a5aeb77  Path: /dev/sdu  Original-path: /dev/sdn  ID: 2a71c7500003000c
                Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error

已嘗試命令: 

scli --clear_sds_device_error --sds_id c948227100000004 --device_path  /dev/sdp
 Successfully cleared SDS device sds: with ID c948227100000004, /dev/sdp

但是當檢查時,query_sds sds_id錯誤是相同的。 

 

Cause

如果您查看 scli --query_sds --sds_id

4: Name: ScaleIO-3a5aeb6e  Path: /dev/sdl  Original-path: /dev/sde  ID: 2a71c74700030003
                Storage Pool: SP_SAS, Capacity: 1116 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error

路徑和原始路徑彼此不同。 

Resolution

  執行下列命令: 

Scli --update_device_original_path --sds_id  --device_id 

例如:

scli --update_device_original_path --sds_id c948227000000003 --device_id  2a71c74700030003
scli --clear_sds_device_error --sds_id  --device_id  
scli --clear_sds_device_error --sds_id c948227100000004 --device_id 2a71c74700030003

注意:使用 device_id 而非使用 device_path 作為裝置路徑在某些時候可能會有所不同,但上述命令將會修正相同的問題。 