Avamar:Data Domain 集成:复制报告“Out of streams”(流外)错误
Summary: 在与 Data Domain 集成的 Avamar 环境中,复制正在完成,但由于出现“Out of streams”(流外)错误而出现异常。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
在与 Data Domain (DD) 集成的 Avamar 环境中,复制部分完成,但日志中显示以下异常:
2019-07-01 17:02:14 avtar Info <41435>: - Data Domain configured in Stand-Alone mode.
2019-07-01 17:02:14 avtar Info <40206>: Setting default storage unit to 'avamar-1315232775' for handle 2
2019-07-01 17:02:14 avtar Info <41440>: Data Domain handle:2 capabilities:0x0020021B
2019-07-01 17:02:14 avtar Info <10609>: Data Domain Destination login to ddxxxx.net complete
2019-07-01 17:02:15 avtar Info <42385>: id:1 Range-Replication selected because it is supported since DDOS 6.0 (container.1.cdsf)
2019-07-01 17:02:15 avtar Info <40160>: - Establishing a connection to the Data Domain system with basic authentication (Connection mode: A:0 E:0).
..
2019-07-01 17:02:18 avtar Info <40160>: - Establishing a connection to the Data Domain system with basic authentication (Connection mode: A:0 E:0).
2019-07-01 17:02:21 avtar Error <0000>: Replication failed - id: 3, unexpected exception caught: ddr_replthread:3:replicateSlice: ddp_filecopy_status failed
[179027] [140372932351744] Mon Jul 1 17:02:21 2019
ddp_filecopy_status() failed, start_offset[0], length[20971520], Err: 5539-filecopy operation failed (nfs: Out of Streams)
[179027] [140372932351744] Mon Jul 1 17:02:19 2019
ddp_filecopy_stop() failed, Err: 5004-nfs filecopy stop failed (nfs: No such file or directory)
...
[179027] [140372992386816] Mon Jul 1 17:02:15 2019
ddp_access() failed, Path avamar-1437556709/STAGING/09a1003e41e2a0d9e3333cf9fbb3345e0b665a0e/BACKUP-01974498BF0587FFD2EC4A97BD201139F29D9516-1D52F902DDF23FC, mode 0 Err: 5004-nfs lookup failed (nfs: No such file or directory)
[179027] [140372992386816] Mon Jul 1 17:02:14 2019
ddp_access() failed, Path avamar-1315232775/STAGING/09a1003e41e2a0d9e3333cf9fbb3345e0b665a0e/BACKUP-01974498BF0587FFD2EC4A97BD201139F29D9516-1D52F902DDF23FC, mode 0 Err: 5004-nfs lookup failed (nfs: No such file or directory)
..
2019-07-01 17:02:29 avtar Info <40176>: - Multi-stream restore summary (current 0, max active 0, max cloned 0, total cloned 0, ddr handle 2):
2019-07-01 17:02:29 avtar FATAL <0000>: Replication failed
2019-07-01 17:02:29 avtar FATAL <40009>: DDR encountered errors.
2019-07-01 17:02:29 avtar Info <9772>: Starting graceful (staged) termination, DDR_ERROR event received (fatal severity) (wrap-up stage)
2019-07-01 17:02:29 avtar Info <0000>: Entering the 'final' phase of termination, DDR_ERROR need to exit)
2019-07-01 17:02:29 avtar Info <40176>: - Multi-stream restore summary (current 0, max active 0, max cloned 0, total cloned 0, ddr handle 2):
2019/07/01-14:02:29.25907 [avtar] INTERNAL ERROR: <0001> assert error (result == MSG_ERR_NONE), /local/jenkins/workspace/server_rollup_hotfix_SLES11-64/src/avtar/ade/adelib/interfaceade.cpp line 396
2019-07-01 17:02:29 avtar Info <5675>: Replicated 0 of 78 backups (0 errors) for client "ddxxxx.net"
2019-07-01 17:02:29 avtar Error <6655>: Replicate interrupted.
2019-07-01 17:02:29 avtar Info <7925>: Restored 940.4 KB from selection(s) with 6.000 GB in 1 files
2019-07-01 17:02:29 avtar Info <6090>: Restored 940.4 KB in 0.34 minutes: 159.9 MB/hour (174 files/hour)
Avamar 和源 Data Domain 以及源和目标 Data Domain 之间的连接已经过验证(在端口 111、2049、2051、2052 上使用 ping、ssh 和 telnet(或 curl))。
Cause
单个复制组包含多个 (4+) 个客户端。
在复制组中,“max-concurrent-processes”设置为 4,从而同时复制四个客户端。
这导致源和目标 Data Domain 之间的流数量多于可用流数量。
Resolution
1.应通过在相应的 Data Domain 上运行以下命令,检查 Data Domain 源和目标上的最大流计数:
ddboost@dd# ddboost streams show active
--------- Active Streams -------- --------- Soft Limits -------- - Hard Limit -
Name Read Write Repl-out Repl-in Read Write Repl Combined Combined
----------------- ---- ----- -------- ------- ---- ----- ---- -------- --------------
avamar-xxxxx 0 0 0 0 - - - - -
----------------- ---- ----- -------- ------- ---- ----- ---- -------- --------------
DD System Stream Limits: read=6 write=35 repl-in=20 repl-out=18 combined=30
2.将允许的最大计数与实际流活动进行比较,如 repl-in 或 repl-out 分别位于目标和源 DD 上。
知识库文章 Data Domain:DDOS 6.0 支持的流计数还包含每个型号支持的流计数列表。本文还包含指向早期 DDOS 版本 4.0 至 5.7 的链接。
3.查看 max-concurrent-processes 和 Maximum number of Data Domain Replication Streams。
4.相应调整以适应源和目标 Data Domain 之间的可用流计数:
-
如果按字母顺序复制客户端:
- 四个客户端将同时复制,创建 24 个流(默认情况下,每个客户端 6 个流)
- 可以使用自由格式标记来更改默认值”
[avtar]ddr-repl-max-parallel-streams“,且在 UI 中值为 1-29。
-
如果并行复制客户端(基于池的复制),则还有一项额外的设置“Data Domain 复制流的最大数量”来控制每个客户端的流数量。
作为资源利用和管理的最佳做法,请确保将客户端划分为多个复制组。
Additional Information
查看复制日志时:
-
“
max-streams“等效于 UI 中的”最大并发进程数”。 -
“
max-ddr-streams“相当于 UI 中的”最大 Data Domain 复制流数”。
Affected Products
Avamar, Avamar ServerArticle Properties
Article Number: 000044317
Article Type: Solution
Last Modified: 30 Sept 2025
Version: 5
Find answers to your questions from other Dell users