ECS:XAM 剪輯的 Centera 至 ECS 遷移失敗

Summary: 使用 XAM API 從 Centera 遷移至 ECS 剪輯期間失敗並顯示格式錯誤。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

嘗試從 Centera IP 對 ECS IP 進行原始讀取和原始開啟時,可在下方看到下列錯誤。
ERROR: Writing clip (com.filepool.fplibrary.FPClip@1234567.Write()) - com.filepool.fplibrary.FPLibraryException: Discriminator [G416C2TF2HB1ABCDEFGHIJKL] format not accepted (basename[BasicBaseName: 19215TEG7CIOGEABCDEFGHIJK]) (transid='ecs-sync.domain/13/WRITE_CLIP'), code: -10005 [Thread-1] CenteraSDK.java:2261 at 2017-02-07 00:35:35,125
NetworkPacket.checkControl(8)<HPPWriteBlobTransaction::run()
如果啟動,可以在遷移應用程式日誌或 SDK 日誌中看到類似的錯誤。 

Cause

ECS 僅在遷移和寫入啟用 CAS 的容器時支援原生 CAS API。ECS 版本資訊概述如下:
"Migration is not supported through sync or native migration because ECS does not take XAM clips. Migration of XAM clips should be done by the customer using native CAS SDK." 

Resolution

ECS 版本資訊記錄了此限制。任何使用 XAM API 寫入的必須遷移到 ECS 的物件都需要事先轉換。

Affected Products

ECS Appliance

Products

ECS Appliance, ECS Appliance Hardware Gen1 U-Series, ECS Appliance Software with Encryption, ECS Appliance Software without Encryption
Article Properties
Article Number: 000048209
Article Type: Solution
Last Modified: 08 Sept 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.