Avamar: Falha no backup do plug-in VSS do Exchange com erro de ACCESS_VIOLATION

Summary: Avamar: Plug-in de VSS do Exchange - falha no backup com "Windows structured exception ACCESS_VIOLATION" devido à incapacidade de executar a verificação de consistência.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Os backups do DAG do Exchange podem falhar com erros semelhantes aos seguintes:
 

015/08/09-23:07:27.17499 [checksg]  ERROR: <0378> threadimpl::runthread() - Windows structured exception ACCESS_VIOLATION in threadID 12068
2015-08-09 18:07:27 avexvss Warning <0378>: threadimpl::runthread() - Windows structured exception ACCESS_VIOLATION in threadID 12068
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 0: RtlDeNormalizeProcessParams()+0x574 [0x7752ada4]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 1: RtlDeNormalizeProcessParams()+0x4a4 [0x7752acd4]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 2: OPENSSL_Applink()+0x16db1a [0x3f3bdc0a]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 3: OPENSSL_Applink()+0x7c6f9 [0x3f2cc7e9]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 4: CCheckSGFiles::operator=()+0xe877b [0x3f1def8b]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 5: CCheckSGFiles::operator=()+0xe880f [0x3f1df01f]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 6: BaseThreadInitThunk()+0xd [0x772d59cd]
2015/08/09-23:07:27.19099 [checksg]  ERROR: <5372> 7: RtlUserThreadStart()+0x21 [0x7750b981]
2015-08-09 18:07:27 avexvss Warning <5372>: 0: RtlDeNormalizeProcessParams()+0x574 [0x7752ada4]
2015-08-09 18:07:27 avexvss Warning <5372>: 1: RtlDeNormalizeProcessParams()+0x4a4 [0x7752acd4]
2015-08-09 18:07:27 avexvss Warning <5372>: 2: OPENSSL_Applink()+0x16db1a [0x3f3bdc0a]
2015-08-09 18:07:27 avexvss Warning <5372>: 3: OPENSSL_Applink()+0x7c6f9 [0x3f2cc7e9]
2015-08-09 18:07:27 avexvss Warning <5372>: 4: CCheckSGFiles::operator=()+0xe877b [0x3f1def8b]
2015-08-09 18:07:27 avexvss Warning <5372>: 5: CCheckSGFiles::operator=()+0xe880f [0x3f1df01f]
2015-08-09 18:07:27 avexvss Warning <5372>: 6: BaseThreadInitThunk()+0xd [0x772d59cd]
2015-08-09 18:07:27 avexvss Warning <5372>: 7: RtlUserThreadStart()+0x21 [0x7750b981]
2015-08-09 18:07:29 avexvss Error <10976>: ERROR: Selected writer 'Microsoft Exchange Writer' reported an error!
   - Status: 1 (VSS_WS_STABLE)
   - Writer Failure code: 0x800423f3 (The writer experienced a transient error. If the backup process is retried, the error may not reoccur).
   - Writer ID: {xxxxxx-xxxx-xxxx-xxxx-xxxxxxx}
   - Instance ID: {xxxx-xxx-xxxx-xxxx-xxxxxxx}
2015-08-09 18:07:29 avexvss Error <19211>: Exception occurred in BackupCompleteEx
2015-08-09 18:07:29 avexvss Error <13077>: Unable to complete backup.

 

Cause

Os backups falham devido à incapacidade de executar a verificação de consistência (usando Eseutil) nos bancos de dados do Exchange.

Resolution

Edite o conjunto de dados para habilitar a opção "Desabilitar verificação de consistência (recomendada somente se houver mais de dois membros no DAG)",

conforme indicado no nome da opção, SOMENTE habilite essa opção se for um grupo de disponibilidade de banco de dados (DAG) do Exchange com dois ou mais nós no cluster.  

Se esse for um servidor Exchange autônomo ou se for necessário permitir a verificação de consistência no Exchange DAG, ajuste os valores para as seguintes opções no conjunto de dados:

 

  • #IOs entre pausas
  • Duração das pausas (ms)

Os valores padrão para ambos os parâmetros são 1000 ms. Tente valores menores, como 500, e monitore o desempenho do backup. Ajuste para cima ou para baixo conforme necessário.

Affected Products

Avamar Plug-in for Exchange VSS

Products

Avamar
Article Properties
Article Number: 000051337
Article Type: Solution
Last Modified: 22 Nov 2024
Version:  4