VPLEX: Distribueret enhedshierarki mangler omfang
Summary: I denne artikel omtales det problem, hvor hierarkiet for distribuerede enheder mangler et omfang, og hvordan det manglende omfang afhjælpes.
Symptoms
Når du får vist komponenthierarkiet for en distribueret enhed, mangler et enhedsben et omfang.VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
consistency-group: CG-CS-Test (synchronous)
virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
storage-array: EMC-CLARiiON-APM00xxxxxxxxx
distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1) <-- The missing extent is expected here. storage-volume: CLARiiON1234_LUN_00030 (1G) logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
storage-array: EMC-CLARiiON-APM00xxxxxxxxx
Når de distribuerede enhedskomponenter er angivet, vises en som et omfang med geometrien "udsnit".VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/
/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name Cluster Child Fully Operational Health Block Block Capacity Geometry Total
---------------------------------- --------- Slot Logged Status State Count Size -------- -------- FreeSpace
---------------------------------- --------- ----- ------ ----------- ------ ------ ----- -------- -------- ---------
device_C2_CLARiiON1234_LUN_00015_1 cluster-2 1 true ok ok 262144 4K 1G raid-0 -
extent_CLARiiON1234_LUN_00030_1 cluster-1 0 true ok ok 262144 4K 1G slice - <-- Note the "Geometry" for this extent is listed as 'slice'.
Cause
Resolution
Løsningen på dette skærmproblem er at bruge interne firmwarekommandoer til at indsætte en ny R0-enhed oven på omfanget. Denne proces vil ikke forårsage nogen påvirkning, men bør kun gennemføres af teknisk support.
Permanent rettelse:
Da dette er et kosmetisk problem, er der ingen permanent løsning på nuværende tidspunkt.
Additional Information
Dette indhold er oversat til 15 sprog: