VPLEX: Hierarkiet for distribuerte enheter mangler

Summary: Denne artikkelen tar for seg problemet der hierarkiet for distribuerte enheter mangler et omfang, og hvordan du løser det manglende omfanget.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



Når du viser komponenthierarkiet for en distribuert enhet, mangler et enhetsben en grad.

VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
  consistency-group: CG-CS-Test (synchronous)
    virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
      distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
        distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
          extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
            storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
              logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
                storage-array: EMC-CLARiiON-APM00xxxxxxxxx
        distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1)

                                                                                                                                            <-- The missing extent is expected here.
          storage-volume: CLARiiON1234_LUN_00030 (1G)
            logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
              storage-array: EMC-CLARiiON-APM00xxxxxxxxx



Når de distribuerte enhetskomponentene er oppført, vises man som et omfang med geometrien "skive".

VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/

/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name                                Cluster    Child  Fully   Operational  Health  Block   Block  Capacity  Geometry  Total
----------------------------------  ---------  Slot   Logged  Status       State   Count   Size   --------  --------  FreeSpace
----------------------------------  ---------  -----  ------  -----------  ------  ------  -----  --------  --------  ---------
device_C2_CLARiiON1234_LUN_00015_1  cluster-2  1      true    ok           ok      262144  4K     1G        raid-0    -
extent_CLARiiON1234_LUN_00030_1     cluster-1  0      true    ok           ok      262144  4K     1G        slice     - <-- N
ote the "Geometry" for this extent is listed as 'slice'.

 

Cause

Dette problemet kan oppstå som et resultat av en omfangsmigrering på volumet, i sjeldne tilfeller. Etter at migreringen er fullført, mangler en R0 (RAID 0)-enhet på toppen av omfanget i komponenthierarkiet.

Resolution

Den manglende R0-enheten i komponenthierarkiet er et kosmetisk problem. Det vil ikke være noen merkbar innvirkning på VPLEX-operasjoner som forlater enheten i denne tilstanden. Hvis du ønsker å løse dette kosmetiske problemet, kan du åpne en serviceforespørsel med VPLEX-støtte og nevne denne artikkelen. 

Løsningen på dette skjermproblemet er å bruke interne fastvarekommandoer til å sette inn en ny R0-enhet på toppen av omfanget. Denne prosessen vil ikke forårsake noen innvirkning, men bør bare fullføres av teknisk støtte.

Permanent løsning:
Siden dette er et kosmetisk problem, er det ingen permanent løsning på dette tidspunktet.

Additional Information

Affected Products

VPLEX Series

Products

VPLEX for All Flash, VPLEX GeoSynchrony, VPLEX Series, VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000167451
Article Type: Solution
Last Modified: 05 Sept 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.