VPLEX: Hierarkiet for distribuerte enheter mangler
Summary: Denne artikkelen tar for seg problemet der hierarkiet for distribuerte enheter mangler et omfang, og hvordan du løser det manglende omfanget.
Symptoms
Når du viser komponenthierarkiet for en distribuert enhet, mangler et enhetsben en grad.VPlexcli:/> show-use-hierarchy distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1
storage-view: Windows (cluster-1)
consistency-group: CG-CS-Test (synchronous)
virtual-volume: device_CLARiiON1234_LUN_00030_1_vol (1G, distributed @ cluster-1, running)
distributed-device: device_CLARiiON1234_LUN_00030_1 (1G, raid-1)
distributed-device-component: device_C2_CLARiiON1234_LUN_00015_1 (1G, raid-0, cluster-2)
extent: extent_C2_CLARiiON1234_LUN_00015_1 (1G)
storage-volume: C2_CLARiiON1234_LUN_00015 (1G)
logical-unit: VPD83T3:60060160xxxxxxxx56343574ffa5e811
storage-array: EMC-CLARiiON-APM00xxxxxxxxx
distributed-device-component: extent_CLARiiON1234_LUN_00030_1 (1G, cluster-1) <-- The missing extent is expected here. storage-volume: CLARiiON1234_LUN_00030 (1G) logical-unit: VPD83T3:60060160xxxxxxxx815405d2daae811
storage-array: EMC-CLARiiON-APM00xxxxxxxxx
Når de distribuerte enhetskomponentene er oppført, vises man som et omfang med geometrien "skive".VPlexcli:/> ll /distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components/
/distributed-storage/distributed-devices/device_CLARiiON1234_LUN_00030_1/distributed-device-components:
Name Cluster Child Fully Operational Health Block Block Capacity Geometry Total
---------------------------------- --------- Slot Logged Status State Count Size -------- -------- FreeSpace
---------------------------------- --------- ----- ------ ----------- ------ ------ ----- -------- -------- ---------
device_C2_CLARiiON1234_LUN_00015_1 cluster-2 1 true ok ok 262144 4K 1G raid-0 -
extent_CLARiiON1234_LUN_00030_1 cluster-1 0 true ok ok 262144 4K 1G slice - <-- Note the "Geometry" for this extent is listed as 'slice'.
Cause
Resolution
Løsningen på dette skjermproblemet er å bruke interne fastvarekommandoer til å sette inn en ny R0-enhet på toppen av omfanget. Denne prosessen vil ikke forårsake noen innvirkning, men bør bare fullføres av teknisk støtte.
Permanent løsning:
Siden dette er et kosmetisk problem, er det ingen permanent løsning på dette tidspunktet.
Additional Information
Dette innholdet er oversatt til 15 språk: