Connectrix B-Series:升級至 Fabric OS 9.1.1c 後,使用「fosexec」命令的 Inline 命令傳回錯誤

Summary: 升級至 Fabric OS (FOS) 9.1.1c 後,無法使用「fosexec」命令,從 UNIX 或 Linux 伺服器執行至交換器的內嵌命令。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

環境:

Fabric OS 9.1.1c

問題:

輸出顯示從 UNIX 或 Linux 伺服器執行內嵌命令時的錯誤。在相同主機殼上探索不同的邏輯交換器 FID 時,命令會停止回應。範例:

[hosttest@VM1234 ~]$
[hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@aa.bb.cc.dd's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
/etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v9.1.1c
         v9.1.1c
---------------------------------------------------

"firmwareshow" on FID 44:

[hosttest@VM3198 ~]$

Cause

此問題是在內部測試期間發現。升級到 FOS 9.2.0a 時,發現錯誤發生變更。

錯誤:
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@10.60.23.25's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v9.2.0a
         v9.2.0a
---------------------------------------------------

"firmwareshow" on FID 44:

[hosttest@VM3198 ~]$

Resolution

解決方案:

升級至 Fabric OS 9.2.0b 或更新版本。

因應措施:

直接在交換器上執行命令。

Additional Information

請參閱 Brocade DEFECT FOS-850854 和 DEFECT FOS-844429,討論此問題。

Affected Products

Connectrix, Connectrix B-Series

Products

Connectrix B-Series Fabric OS 9.X
Article Properties
Article Number: 000218645
Article Type: Solution
Last Modified: 29 July 2025
Version:  4