Isilon PowerScale:重新製作映像程序失敗,並達到停止開機條件
Summary: 由於磁碟分割已髒,無法重建 Isilon 或 PowerScale 節點的映像。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
為 Isilon 或 PowerScale 節點重建映像時,會顯示類似此訊息:
Unable to pull files from None backup Installation config method is PSF: Unable to pull secondary backup files Installation config method is PSF: Copying PSI config files Unable to /sbin/mount /dev/mirror/mfg on /mfg PSF file path /mfg/psi/psf.json unmounted primary backup; mount attempt failed stop_boot condition reached, but OneFS install flag set. Aborting. Failed to copy PSI config files: Chassis is missing a PSI receipt. A receipt must be provided before the boot will be allowed to continue. [: -ne: unexpected operator eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory eval: cannot create /opt/dell/srvadmin/iSM/etc/ini/software-package.ini: No such file or directory eval: /opt/dell/srvadmin/iSM/bin/Invoke-iSMPKIHelper: not found Starting background file system checks in 60 seconds. Thu Mar 28 21:44:58 GMT 2024 Isilon OneFS/amd64 (isi-bsd) (ttyu0) login:
Cause
鏡像先前被標記為已髒,需要檔案系統檢查才能解決。
Resolution
使用 root 的使用者名稱和密碼登入作業系統,然後執行:
fsck -y -t ufs /dev/mirror/*
如果命令指示它已修復任何鏡像,請重新運行該命令。繼續重新運行該命令,直到鏡像報告沒有變化。
當鏡像標示為乾淨後,請為節點重新開機,重建映像程序應會完成。如果重建映像程序持續發生問題,請聯絡支援人員。
Affected Products
Isilon Gen6.5, Isilon Gen6Article Properties
Article Number: 000223642
Article Type: Solution
Last Modified: 02 Apr 2024
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.