PowerFlex 無法清除 SDS 裝置錯誤 - 裝置狀態在作業系統層級為離線

Summary: 使用 SDS「清除裝置錯誤」無法運作,且裝置仍處於錯誤或故障狀態。 當 SDS 裝置上有許多同時發生的裝置錯誤時,管理裝置的作業系統可能會使裝置離線。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

案例

SDS 裝置故障或報告錯誤,嘗試使用 SDS「清除裝置錯誤」時,裝置會一直處於錯誤或故障狀態。

症狀

ScaleIO 系統事件回報磁碟裝置錯誤或故障:

 799   2016-01-22 17:28:39.818 SDS_DEV_ERROR_REPORT      ERROR    Device error reported on SDS: 10.3.1.21, Device: /dev/sdb. State: NORMAL upDownState: UP processState: DEV_ERR_INPROGRESS devErrState: REPORT 

查詢 SDS 報告磁碟裝置錯誤或故障:

 ScaleIO-10-1-1-202:~ # scli --query_sds --sds_id 9780122600000003

Device information (total 8 devices):
         1: Name: ScaleIO-6a0a6209  Path: /dev/sdb  Original-path: /dev/sdb  ID: 851f01c100030000
                Storage Pool: SASPOOL, Capacity: 1675 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal
         2: Name: ScaleIO-6a0a620a  Path: /dev/sdc  Original-path: /dev/sdc  ID: 851f01c200030001
                Storage Pool: SASPOOL, Capacity: 1675 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal
         3: Name: ScaleIO-6a0a620b  Path: /dev/sdd  Original-path: /dev/sdd  ID: 851f01c300030002
                Storage Pool: SASPOOL, Capacity: 1675 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal
         4: Name: ScaleIO-6a0a620c  Path: /dev/sde  Original-path: /dev/sde  ID: 851f01c400030003
                Storage Pool: SSDPOOL, Capacity: 1489 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal
         5: Name: ScaleIO-6a0a620d  Path: /dev/sdf  Original-path: /dev/sdf  ID: 851f01c500030004
                Storage Pool: SASPOOL, Capacity: 1675 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Error
         6: Name: ScaleIO-6a0a620e  Path: /dev/sdg  Original-path: /dev/sdg  ID: 851f01c600030005
                Storage Pool: SSDPOOL, Capacity: 1489 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal
         7: Name: ScaleIO-6a0a620f  Path: /dev/sdh  Original-path: /dev/sdh  ID: 851f01c700030006
                Storage Pool: SASPOOL, Capacity: 1675 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal
         8: Name: ScaleIO-6a0a6210  Path: /dev/sdi  Original-path: /dev/sdi  ID: 851f01c800030007
                Storage Pool: SASPOOL, Capacity: 1675 GB Error-fixes: 0 scanned 0 MB, Compare errors: 0 State: Normal

SVM/Linux 訊息檔案報告離線裝置:

 Jan 22 17:28:35 ScaleIO-10-1-1-201 kernel: [45678.865605] end_request: I/O error, dev sdg, sector 1138313984
Jan 22 17:28:37 ScaleIO-10-1-1-201 kernel: [45681.452800] sd 2:0:6:0: [sdg] task abort on host 2, ffff8800b83f6e80
Jan 22 17:28:37 ScaleIO-10-1-1-201 kernel: [45681.452877] sd 2:0:1:0: [sdb] task abort on host 2, ffff8801b7476d80
Jan 22 17:28:37 ScaleIO-10-1-1-201 kernel: [45681.453086] sd 2:0:8:0: [sdh] task abort on host 2, ffff8800b83f6280
Jan 22 17:28:37 ScaleIO-10-1-1-201 kernel: [45681.453109] sd 2:0:8:0: [sdh] task abort on host 2, ffff8800a37a6c80
Jan 22 17:28:37 ScaleIO-10-1-1-201 kernel: [45681.453133] sd 2:0:9:0: [sdi] task abort on host 2, ffff8800b83f6b80
Jan 22 17:28:47 ScaleIO-10-1-1-201 kernel: [45691.537180] sd 2:0:5:0: rejecting I/O to offline device

磁碟裝置上的 ESXi VMkernel 記錄報告錯誤:

 2016-01-22T09:40:21.801Z cpu1:33420)ScsiDeviceIO: 7024: Could not detect setting of QErr for device naa.614187704f3b47001e34b585468abf85. Error Not supported.
2016-01-22T09:40:21.801Z cpu1:33420)ScsiDeviceIO: 7538: Could not detect setting of sitpua for device naa.614187704f3b47001e34b585468abf85. Error Not supported.
2016-01-22T09:40:21.801Z cpu5:33593)NMP: nmp_ThrottleLogForDevice:3178: Cmd 0x28 (0x439e1a830cc0, 0) to dev "naa.614187704f3b47001e34b585468abf85" on path "vmhba1:C2:T1:L0" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x0. Act:NONE
2016-01-22T09:40:21.801Z cpu5:33593)ScsiDeviceIO: 2607: Cmd(0x439e1a830cc0) 0x28, CmdSN 0xd62 from world 0 to dev "naa.614187704f3b47001e34b585468abf85" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x0.
2016-01-22T09:40:21.801Z cpu5:33593)ScsiCore: 1609: Power-on Reset occurred on naa.614187704f3b47001e34b585468abf85
2016-01-22T09:40:21.844Z cpu5:33593)NMP: nmp_ThrottleLogForDevice:3178: Cmd 0x1a (0x439e1a830cc0, 0) to dev "naa.614187704f3b47001e34b585468abf85" on path "vmhba1:C2:T1:L0" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x24 0x0. Act:NONE
2016-01-22T09:40:21.844Z cpu5:33593)ScsiDeviceIO: 2645: Cmd(0x439e1a830cc0) 0x1a, CmdSN 0xd66 from world 0 to dev "naa.614187704f3b47001e34b585468abf85" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x24 0x0.
2016-01-22T09:40:21.844Z cpu1:33420)ScsiDevice: 3835: Successfully registered device "naa.614187704f3b47001e34b585468abf85" from plugin "NMP" of type 0
2016-01-22T09:40:21.844Z cpu1:33420)NMP: nmp_DeviceUpdateProtectionInfo:569: Set protection info for device 'naa.614187704f3b47001e34b585468abf85', Enabled: 0 ProtType: 0x0 Guard: 0x0 ProtMask: 0x0
2016-01-22T22:27:49.085Z cpu19:33115)WARNING: NMP: nmpDeviceTaskMgmt:2284: Attempt to issue lun reset on device naa.614187704f3b47001e34b585468abf85. This will clear any SCSI-2 reservations on the device.

影響

磁碟裝置維持為故障。
您無法清除 SDS 裝置錯誤。

Cause

當磁碟裝置出現問題,且磁碟裝置因任何原因沒有回應時,作業系統會使磁碟裝置離線。
 
注意:如果磁碟裝置故障,裝置不會回到線上狀態,而且可能需要更換磁碟裝置。

Resolution

因應措施

SVM - Linux 環境:

  1. 確認 磁碟裝置目前的狀態:
[root@ssltest ~]# cat /sys/block/sdx/device/state
offline 
  1. 如果磁碟裝置標示為「離線」,請使用下列命令 將磁碟裝置「連線」
echo "running" > /sys/block/sdx/device/state
  1. 使用 SCLI 或 UI 清除 SDS 裝置 錯誤。


Windows 環境:

  1. 使用「邏輯磁碟管理員」或磁碟零件驗證磁碟裝置目前的狀態:
C:\>diskpart
Microsoft DiskPart version 6.1.7601
Copyright (C) 1999-2008 Microsoft Corporation.
On computer: ISENABLOVSL1C
DISKPART> list disk
  Disk ###  Status         Size     Free     Dyn  Gpt
  --------  -------------  -------  -------  ---  ---
  Disk 0    Online          238 GB      0 B
DISKPART> 
  1. 如果磁碟裝置標示為「離線」,請使用下列命令 將磁碟裝置「連線」, 或使用「邏輯磁碟管理員」:
DISKPART> online disk


任何作業系統上線上磁碟裝置的替代選項:


注意:此選項需要「停機時間」,並在 ScaleIO 系統上觸發重建/重新平衡
 
  1. 如果可能,請將 SDS 輸入維護 模式
  2. 重新開機 SDS 伺服器
  3. 結束維護模式 (若在步驟 1 完成)
  4. 清除 SDS 裝置錯誤 (使用 UI 或 CLI)
  5. 在 ScaleIO 中確認裝置狀態

Affected Products

PowerFlex rack, ScaleIO
Article Properties
Article Number: 000281632
Article Type: Solution
Last Modified: 06 Mar 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.