PowerFlex 無法將待機節點新增至 MDM 叢集
Summary: 無法將待機節點新增至 MDM 叢集。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
嘗試將從屬 MDM 節點更換為待機節點時,在事件記錄中出現下列錯誤:
22892 2017-10-03 07:50:21.908 CLI_COMMAND_FAILED WARNING Command REPLACE_CLUSTER_MDM was not successful. Error code: The MDM could not be found [3982]
使用的命令為:
#scli --replace_cluster_mdm --add_slave_mdm_name Manager2 --remove_slave_mdm_name Manager3 --allow_leave_failed --i_am_sure
其中查詢全部如下所示:
#scli --query_cluster Cluster: Name: SIO: 3_node, State: Normal, Active: 3/3, Replicas: 2/2 Master MDM: Name: Manager1 ID: 0x123456789 IPs: X.X.Y.X, X.X.Y.X, Management IPs: X.X.X.X, Port: 9011 Version: 2.0.5014 Slave MDMs: Name: Manager3, ID: 0x987654321 IPs: X.X.Y.X, X.X.Y.X, Management IPs: X.X.X.X Status: Normal, Version: 2.0.5014 Tie-Breakers: Name: TB1, ID: 0x213546789 IPs: X.X.X.X, X.X.X.X, Port: 9011 Status: Normal, Version: 2.0.5014 Standby MDMs: Name: Manager2, ID: 0x2455547834b33141, Manager IPs: X.X.X.X, X.X.X.X, Management IPs: X.X.X.X, Port: 9011 Name: TB, ID: 0x123457689, Tie Breaker IPs: X.XX.X, x.x.x.x, Port: 9011
Cause
未在待機節點上安裝 MDM 套件。
Resolution
移除備用節點:
#scli --remove_standby_mdm --remove_mdm_name Manager2 Install the MDM package on the standby mode - for svm:
#MDM_ROLE_IS_MANAGER=1 rpm -i < package > Add the standby node back to the cluster:
#scli --add_standby_mdm --mdm_role manager --new_mdm_ip x.x.x.x,x.x.x.x --new_mdm_name Manager2 --new_mdm_management_ip x.x.x.x Then run the '--replace_cluster_mdm ' command again.
Additional Information
Affected Products
PowerFlex rack, VxFlex Product FamilyArticle Properties
Article Number: 000033324
Article Type: Solution
Last Modified: 29 Jan 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.