Scenario
SDC installert på Linux
Volumer som er tilordnet SDC, tildeles fra et lagringsutvalg som er konfigurert til å bruke kontrollsum.
Systemet opplever minnemangel eller fragmentering av minne.

Symptomer
Meldinger som ligner på følgende vises i syslog, vanligvis: /var/log/messages

Dec 12 15:36:09 server002 kernel: kworker/16:2H: page allocation failure: order:8, mode:0x104020 
Dec 12 15:36:09 server002 kernel: CPU: 16 PID: 11460 Comm: kworker/16:2H Tainted: P OE ------------ 3.10.0-514.21.1.el7.x86_64 #1 
Dec 12 15:36:09 server002 kernel: Hardware name: HP ProLiant DL560 Gen9/ProLiant DL560 Gen9, BIOS P85 01/04/2016 
Dec 12 15:36:09 server002 kernel: Workqueue: kblockd blk_delay_work 
Dec 12 15:36:09 server002 kernel: 0000000000104020 0000000054aac964 ffff886aecfd37c0 ffffffff81686e13 
Dec 12 15:36:09 server002 kernel: ffff886aecfd3850 ffffffff81187090 ffff88607ffda000 0000000000000010 
Dec 12 15:36:09 server002 kernel: ffffffffffffff00 0010402000000000 0022522000000000 0000000054aac964 
Dec 12 15:36:09 server002 kernel: Call Trace: 
Dec 12 15:36:09 server002 kernel: [<ffffffff81686e13>] dump_stack+0x19/0x1b 
Dec 12 15:36:09 server002 kernel: [<ffffffff81187090>] warn_alloc_failed+0x110/0x180 
Dec 12 15:36:09 server002 kernel: [<ffffffff816829a7>] __alloc_pages_slowpath+0x6b7/0x725 Dec 12 15:36:09 server002 kernel: [<ffffffff8118b645>] __alloc_pages_nodemask+0x405/0x420 Dec 12 15:36:09 server002 kernel: [<ffffffff811cf7fa>] alloc_pages_current+0xaa/0x170 
Dec 12 15:36:09 server002 kernel: [<ffffffff81185f6e>] __get_free_pages+0xe/0x50 
Dec 12 15:36:09 server002 kernel: [<ffffffff811db09e>] kmalloc_order_trace+0x2e/0xa0 
Dec 12 15:36:09 server002 kernel: [<ffffffff811dd871>] __kmalloc+0x221/0x240 
Dec 12 15:36:09 server002 kernel: [<ffffffff811de7c3>] ? kmem_cache_alloc+0x193/0x1e0 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07b697a>] blkIO_OnChecksumIoStart+0x5a/0x550 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07ed587>] ? mosMCAllocator_Alloc+0x57/0xa0 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07b3ac1>] blkIO_HandleChecksumOnIoStart+0xc1/0x220 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07b7ea8>] mapVolIO_Do_CK+0x398/0x1e80 [scini] Dec 12 15:36:09 server002 kernel: [<ffffffffa07b4306>] blkIO_Do_CK+0x266/0xa00 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07e9838>] mosMit_EntryWrapper+0x128/0x1b0 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07e9a2c>] mosMit_StartNow+0x7c/0x90 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffffa07b4ea6>] blkIO_Request+0x356/0x730 [scini] 
Dec 12 15:36:09 server002 kernel: [<ffffffff810cf27e>] ? dequeue_task_fair+0x41e/0x660 
Dec 12 15:36:09 server002 kernel: [<ffffffff812eb7e3>] __blk_run_queue+0x33/0x40 
Dec 12 15:36:09 server002 kernel: [<ffffffff812ed915>] blk_delay_work+0x25/0x60 
Dec 12 15:36:09 server002 kernel: [<ffffffff810a845b>] process_one_work+0x17b/0x470 
Dec 12 15:36:09 server002 kernel: [<ffffffff810a9296>] worker_thread+0x126/0x410 
Dec 12 15:36:09 server002 kernel: [<ffffffff810a9170>] ? rescuer_thread+0x460/0x460 
Dec 12 15:36:09 server002 kernel: [<ffffffff810b0a4f>] kthread+0xcf/0xe0 
Dec 12 15:36:09 server002 kernel: [<ffffffff810b0980>] ? kthread_create_on_node+0x140/0x140 Dec 12 15:36:09 server002 kernel: [<ffffffff81697418>] ret_from_fork+0x58/0x90 
Dec 12 15:36:09 server002 kernel: [<ffffffff810b0980>] ? kthread_create_on_node+0x140/0x140

Meldingene begynner med: page allocation failure
Stakksporingen inkluderer: blkIO_HandleChecksumOnIoStart

Innvirkning
Det kan hende at den interne kontrollsummekanismen i ScaleIO ikke verifiserer enkelte I/O-operasjoner.

Merk: TCP-meldingene som sendes mellom SDC og SDS, inkluderer en kontrollsum på TCP-nivå, uavhengig av kontrollsummen som er lagt til av SDC, som brukes til å bekrefte innholdet i meldingen som en del av TCP-stakken.

 

Cause

Når kontrollsumfunksjonen er aktivert i et lagringsutvalg, har I/O-operasjoner på volumer som er tildelt fra lagringsgruppen, en kontrollsum inkludert i nettverksmeldingene mellom SDC og SDS.
For å beregne disse kontrollsumverdiene tildeler SDC minne dynamisk.
Hvis verten lider av minnemangel eller minnefragmentering, kan minnetildelingen som kreves for kontrollsumoperasjonen, mislykkes.

Når minnetildelingen mislykkes, kan SDC ikke beregne kontrollsummen, og legger den ikke ved nettverksmeldingen.
Når SDS mottar en melding fra SDC, som ikke inneholder en kontrollsum, utfører den I / O-operasjonen uten å verifisere innholdet i meldingen på siden.

For å konkludere, har minneallokeringsfeilene ingen innvirkning på applikasjonenes I / O-operasjoner eller ScaleIO-ytelse.

 

Resolution

Hvis det er mulig, må du kontrollere at verten har nok ledig ufragmentert minne.

Berørte versjoner
Alle ScaleIO-versjoner - fungerer som designet

Løst i versjon
N/A

 

Article Properties
Article Number: 000161109
Article Type: Solution
Last Modified: 03 Sept 2025
Version:  7
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.