PowerStore: Systemtilstandstjekket mislykkes for "BBU Sensor Check node_x FAILED Uoverensstemmende varenummer registreret på node X (KB#000196197)"

Summary: Kørsel af PowerStore-systemets tilstandskontrol mislykkes for "BBU Sensor Check node_x FAILED Uoverensstemmende varenummer registreret på node X (KB#000196197)"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

System Health Check (SHC)-testen af "bbu_sensor_check" mislykkes på begge noder og rapporterer "Uoverensstemmende delnummer registreret"
 
[SVC:service@XXXXXXX-A user]$ svc_health_check run


 
{code}
Name                               Location  Status     Description                                                                                                                                                                    
Internal Disk Space                node_a    PASSED                                                                                                                                                                                    
Internal Disk Space                node_b    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_a    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_b    PASSED                                                                                                                                                                                    
ICD Network Connectivity Check     node_a    PASSED     Test not needed for Block only (Single appliance) or HCI                                                                                                                       
Drive Flags Check                  node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_b    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_a    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_b    PASSED                                                                                                                          
Disk Health                        node_a    PASSED                                                                                                                                                                                    
DIMM Health                        node_a    PASSED                                                                                                                                                                                    
OS package name check              node_a    PASSED                                                                                                                                                                                    
Active System Alerts Check         node_a    PASSED                                                                                                                                                                                    
External Management Network        node_a    PASSED                                                                                                                                                                                    
Symmetric ICM Connection Check     node_a    PASSED                                                                                                                                                                                    
Time skew Check                    node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_b    PASSED                                                                                                                                                                                    
recovery partition image check     node_a    PASSED                                                                                                                                                                                    
recovery partition image check     node_b    PASSED                                                                                                                                                                                    
REST Authorization Service         node_a    PASSED                                                                                                                                                                                    
REST Authorization Service         node_b    PASSED                                                                                                                                                                                    
Fru FW Upgrade Flag Check          node_a    PASSED                                                                                                                                                                                    
Initiator Connectivity Redundancy  node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_b    PASSED                                                                                                                                                                                    
Pre-Upgrade Check                  node_a    WARNING                                                                                                                                                                                   
Pre-Upgrade Check                  node_b    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_a    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_b    PASSED                                                                                                                                                                                    
REST Configuration Service         node_a    PASSED                                                                                                                                                                                    
REST Data Service                  node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_b    PASSED                                                                                                                                                                                    
Component SN Check                 node_a    PASSED                                                                                                                                                                                    
Component SN Check                 node_b    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_a    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_b    PASSED                                                                                                                                                                                    
kms lockbox file check             node_a    PASSED                                                                                                                                                                                    
Internal File System               node_a    PASSED                                                                                                                                                                                    
Internal File System               node_b    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_a    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_b    PASSED                                                                                                                                                                                    
Internal Management Network        node_a    WARNING                                                                                                                                                                                   
SAS Expansion Enclosure Check      node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_b    PASSED                                                                                                                                                                                    
cyc_node space check               node_a    PASSED                                                                                                                                                                                    
cyc_node space check               node_b    PASSED                                                                                                                                                                                    

BBU Sensor Check                   node_a    FAILED     Mismatched part number detected on node A (KB#000196197)                                                                                                                       
BBU Sensor Check                   node_b    FAILED     Mismatched part number detected on node B (KB#000196197)
  
Brugergrænsefladens interne visning af hardwarekomponenter viser BBU Healthy for begge noder, men BBU-varenummeret er forskelligt på hver node.

BBU-hardwarekomponent Vis node A

BBU-hardwarekomponent Se node B

svc_diag hardwarekontrol på både node A og node B viser, at BBU'er er OK.
Kør kommandoen mod begge noder.
$ svc_diag list --hardware --sub_options fault_status
 
Hardware: ========== Fault Status register  ===========

Memory       dimm00: OK  | dimm01: OK  | dimm02: OK  | dimm03: OK  | dimm04: OK  | dimm05: OK  | dimm06: OK  | dimm07: OK  | 
             dimm08: OK  | dimm09: OK  | dimm10: OK  | dimm11: OK  | dimm12: OK  | dimm13: OK  | dimm14: OK  | dimm15: OK  | 
             dimm16: OK  | dimm17: OK  | dimm18: OK  | dimm19: OK  | dimm20: OK  | dimm21: OK  | dimm22: OK  | dimm23: OK  | 
EmbeddedDrve Drive00: OK  | Drive01: OK  | 
BackEndDrive Drive00: OK  | Drive01: OK  | Drive02: OK  | Drive03: OK  | Drive04: OK  | Drive05: OK  | Drive06: OK  | Drive07: OK  | 
             Drive08: OK  | Drive09: OK  | Drive10: OK  | Drive11: OK  | Drive12: OK  | Drive13: OK  | Drive14: OK  | Drive15: OK  | 
             Drive16: OK  | Drive17: OK  | Drive18: OK  | Drive19: OK  | Drive20: OK  | Drive21: OK  | Drive22: OK  | Drive23: OK  | 
             Drive24: OK  | 
I/O Module   iom00: OK  | iom01: OK  | 
Mezz         mez00: OK  | mez01: OK  | 
PSU          psu00: OK  | psu01: OK  | 

BBU          bbu00: OK  | bbu01: OK  | 
FAN          fan00: OK  | fan01: OK  | fan02: OK  | fan03: OK  | fan04: OK  | fan05: OK  | fan06: OK  | fan07: OK  | 
             fan08: OK  | fan09: OK  | fan10: OK  | fan11: OK  | fan12: OK  | fan13: OK  | 
Root I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
IO I2C       i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Other I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Mezz I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Drive I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
             i2c08: OK  | i2c09: OK  | i2c10: OK  | i2c11: OK  | i2c12: OK  | i2c13: OK  | i2c14: OK  | i2c15: OK  | 
             i2c16: OK  | i2c17: OK  | i2c18: OK  | i2c19: OK  | i2c20: OK  | i2c21: OK  | i2c22: OK  | i2c23: OK  | 
             i2c24: OK  | 

System       Bit  0  CPU Module: OK 
             Bit  1  Management Module: OK 
             Bit  2  Drive I/O Card 0: OK 
             Bit  3  eFlash : OK 
             Bit  4  Expansion Bay 0: OK 
             Bit  5  Enclosure: OK 
             Bit  6  CMI: OK 
             Bit  7  All Frus: OK 
             Bit  8  External: OK 
             Bit  9  Expansion Bay 1: OK 
             Bit 10  Drive I/O Card 1: OK                  

svc_diag viser forskellige varenumre for BBU 0 og 1.
Kør kommandoen mod begge noder.
$ svc_diag list --hardware --sub_options inventory |grep -A5 Battery
 
FRU Device Description : Battery0 (ID 9)
Board Mfg Date        : Tue Aug 18 00:00:00 2020
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPW4211500063  
Board Part Number     :
078-000-177-02  
--
FRU Device Description : Battery1 (ID 10)
Board Mfg Date        : Wed Dec 11 00:00:00 2019
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPV8200500140  
Board Part Number     :
078-000-168-02  
 

Cause

Der er et problem i de nyeste tynde pakker til PowerStoreOS 2.1.x og 3.x, som fejlagtigt kontrollerer BBU-delnummeret mellem de to noder og mislykkes, hvis de ikke er ens.

Alle pakker med helbredstjek af systemet siden PowerStore-health_check-2.1.1.1-1736451 til PowerStoreOS 2.1.X er berørt.
Alle pakker med helbredstjek af systemet siden PowerStore-health_check-3.0.0.0-1781415 til PowerStoreOS 3.X er berørt.

PowerStore understøtter 11 forskellige BBU-delnumre, og systemtilstandstjekket forventer, at PN for begge BBU'er er den samme, hvilket muligvis ikke er tilfældet. Alle nedenstående varenumre er gyldige og understøttes.
078-000-168-02 078-000-177-02 078-000-192-00 078-000-195-03 078-000-211-01 088-000-168-02 088-000-177-02 088-000-192-00 088-000-195-03

088-000-211-00 088-000-211-01







Resolution

Hvis BBU'erne er i en sund tilstand, og den eneste fejl, der opstår ved at køre systemets tilstandskontrol af den tynde pakke, er "BBU Sensor Check node_x FAILED Uoverensstemmende varenummer registreret på node X (KB#000196197)," kan fejlen ignoreres, og NDU kan startes.

Dette er rettet i en ny udgivelse af tynde pakker til systemsundhedstjek, der er under udvikling.

Affected Products

PowerStore
Article Properties
Article Number: 000212653
Article Type: Solution
Last Modified: 29 Jul 2025
Version:  6