PowerStore: Il controllo integrità del sistema non riesce per "BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)"

Summary: L'esecuzione del controllo integrità del sistema PowerStore non riesce per "BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Il test SHC (System Health Check) di "bbu_sensor_check" ha esito negativo su entrambi i nodi, segnalando "Mismatched part number detected"
 
[SVC:service@XXXXXXX-A user]$ svc_health_check run


 
{code}
Name                               Location  Status     Description                                                                                                                                                                    
Internal Disk Space                node_a    PASSED                                                                                                                                                                                    
Internal Disk Space                node_b    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_a    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_b    PASSED                                                                                                                                                                                    
ICD Network Connectivity Check     node_a    PASSED     Test not needed for Block only (Single appliance) or HCI                                                                                                                       
Drive Flags Check                  node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_b    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_a    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_b    PASSED                                                                                                                          
Disk Health                        node_a    PASSED                                                                                                                                                                                    
DIMM Health                        node_a    PASSED                                                                                                                                                                                    
OS package name check              node_a    PASSED                                                                                                                                                                                    
Active System Alerts Check         node_a    PASSED                                                                                                                                                                                    
External Management Network        node_a    PASSED                                                                                                                                                                                    
Symmetric ICM Connection Check     node_a    PASSED                                                                                                                                                                                    
Time skew Check                    node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_b    PASSED                                                                                                                                                                                    
recovery partition image check     node_a    PASSED                                                                                                                                                                                    
recovery partition image check     node_b    PASSED                                                                                                                                                                                    
REST Authorization Service         node_a    PASSED                                                                                                                                                                                    
REST Authorization Service         node_b    PASSED                                                                                                                                                                                    
Fru FW Upgrade Flag Check          node_a    PASSED                                                                                                                                                                                    
Initiator Connectivity Redundancy  node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_b    PASSED                                                                                                                                                                                    
Pre-Upgrade Check                  node_a    WARNING                                                                                                                                                                                   
Pre-Upgrade Check                  node_b    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_a    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_b    PASSED                                                                                                                                                                                    
REST Configuration Service         node_a    PASSED                                                                                                                                                                                    
REST Data Service                  node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_b    PASSED                                                                                                                                                                                    
Component SN Check                 node_a    PASSED                                                                                                                                                                                    
Component SN Check                 node_b    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_a    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_b    PASSED                                                                                                                                                                                    
kms lockbox file check             node_a    PASSED                                                                                                                                                                                    
Internal File System               node_a    PASSED                                                                                                                                                                                    
Internal File System               node_b    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_a    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_b    PASSED                                                                                                                                                                                    
Internal Management Network        node_a    WARNING                                                                                                                                                                                   
SAS Expansion Enclosure Check      node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_b    PASSED                                                                                                                                                                                    
cyc_node space check               node_a    PASSED                                                                                                                                                                                    
cyc_node space check               node_b    PASSED                                                                                                                                                                                    

BBU Sensor Check                   node_a    FAILED     Mismatched part number detected on node A (KB#000196197)                                                                                                                       
BBU Sensor Check                   node_b    FAILED     Mismatched part number detected on node B (KB#000196197)
  
La vista interna del componente hardware dell'interfaccia utente mostra l'integrità della BBU per entrambi i nodi, ma il numero parte BBU è diverso su ogni nodo.

Nodo A di visualizzazione componente hardware BBU

Nodo BBU visualizzazione componente hardware B

svc_diag controllo dell'hardware sul nodo A e sul nodo B mostrano che le BKU sono OK.
Eseguire il comando su entrambi i nodi.
$ svc_diag list --hardware --sub_options fault_status
 
Hardware: ========== Fault Status register  ===========

Memory       dimm00: OK  | dimm01: OK  | dimm02: OK  | dimm03: OK  | dimm04: OK  | dimm05: OK  | dimm06: OK  | dimm07: OK  | 
             dimm08: OK  | dimm09: OK  | dimm10: OK  | dimm11: OK  | dimm12: OK  | dimm13: OK  | dimm14: OK  | dimm15: OK  | 
             dimm16: OK  | dimm17: OK  | dimm18: OK  | dimm19: OK  | dimm20: OK  | dimm21: OK  | dimm22: OK  | dimm23: OK  | 
EmbeddedDrve Drive00: OK  | Drive01: OK  | 
BackEndDrive Drive00: OK  | Drive01: OK  | Drive02: OK  | Drive03: OK  | Drive04: OK  | Drive05: OK  | Drive06: OK  | Drive07: OK  | 
             Drive08: OK  | Drive09: OK  | Drive10: OK  | Drive11: OK  | Drive12: OK  | Drive13: OK  | Drive14: OK  | Drive15: OK  | 
             Drive16: OK  | Drive17: OK  | Drive18: OK  | Drive19: OK  | Drive20: OK  | Drive21: OK  | Drive22: OK  | Drive23: OK  | 
             Drive24: OK  | 
I/O Module   iom00: OK  | iom01: OK  | 
Mezz         mez00: OK  | mez01: OK  | 
PSU          psu00: OK  | psu01: OK  | 

BBU          bbu00: OK  | bbu01: OK  | 
FAN          fan00: OK  | fan01: OK  | fan02: OK  | fan03: OK  | fan04: OK  | fan05: OK  | fan06: OK  | fan07: OK  | 
             fan08: OK  | fan09: OK  | fan10: OK  | fan11: OK  | fan12: OK  | fan13: OK  | 
Root I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
IO I2C       i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Other I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Mezz I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Drive I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
             i2c08: OK  | i2c09: OK  | i2c10: OK  | i2c11: OK  | i2c12: OK  | i2c13: OK  | i2c14: OK  | i2c15: OK  | 
             i2c16: OK  | i2c17: OK  | i2c18: OK  | i2c19: OK  | i2c20: OK  | i2c21: OK  | i2c22: OK  | i2c23: OK  | 
             i2c24: OK  | 

System       Bit  0  CPU Module: OK 
             Bit  1  Management Module: OK 
             Bit  2  Drive I/O Card 0: OK 
             Bit  3  eFlash : OK 
             Bit  4  Expansion Bay 0: OK 
             Bit  5  Enclosure: OK 
             Bit  6  CMI: OK 
             Bit  7  All Frus: OK 
             Bit  8  External: OK 
             Bit  9  Expansion Bay 1: OK 
             Bit 10  Drive I/O Card 1: OK                  

svc_diag mostra diversi numeri parte per BBU 0 e 1.
Eseguire il comando su entrambi i nodi.
$ svc_diag list --hardware --sub_options inventory |grep -A5 Battery
 
FRU Device Description : Battery0 (ID 9)
Board Mfg Date        : Tue Aug 18 00:00:00 2020
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPW4211500063  
Board Part Number     :
078-000-177-02  
--
FRU Device Description : Battery1 (ID 10)
Board Mfg Date        : Wed Dec 11 00:00:00 2019
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPV8200500140  
Board Part Number     :
078-000-168-02  
 

Cause

C'è un problema nei più recenti pacchetti thin di controllo dello stato del sistema per PowerStoreOS 2.1.x e 3.x, che controlla erroneamente il numero parte BBU tra i due nodi e non riesce se non sono gli stessi.

Sono interessati tutti i pacchetti di controllo integrità del sistema a partire da PowerStore-health_check-2.1.1.1-1736451 per PowerStoreOS 2.1.X.
Sono interessati tutti i pacchetti di controllo integrità del sistema a partire da PowerStore-health_check-3.0.0.0-1781415 per PowerStoreOS 3.X.

PowerStore supporta 11 part number BBU diversi e il controllo integrità del sistema prevede che il PN di entrambe le BBU sia lo stesso, il che potrebbe non essere il caso. Uno dei seguenti numeri parte è valido e supportato.
078-000-168-02 078-000-177-02 078-000-192-00 078-000-195-03
078-000-211-01 088-000-168-02 088-000-177-02 088-000-192-00
088-000-195-03
088-000-211-00
088-000-211-01





Resolution

Se le BBU sono in uno stato integro e l'unico errore prodotto dall'esecuzione del controllo dello stato del sistema che indica che il thin pacchetto è "BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)", l'errore può essere ignorato e l'NDU può essere avviato.

Questo problema è stato risolto in una nuova versione del controllo dello stato del sistema dei thin pacchetti in fase di sviluppo.