PowerStore: System Health Check fails for "BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)"

Summary: Running the PowerStore system health check fails for "BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The System Health Check (SHC) test of "bbu_sensor_check" fails on both Nodes, reporting "Mismatched part number detected"
 
[SVC:service@XXXXXXX-A user]$ svc_health_check run


 
{code}
Name                               Location  Status     Description                                                                                                                                                                    
Internal Disk Space                node_a    PASSED                                                                                                                                                                                    
Internal Disk Space                node_b    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_a    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_b    PASSED                                                                                                                                                                                    
ICD Network Connectivity Check     node_a    PASSED     Test not needed for Block only (Single appliance) or HCI                                                                                                                       
Drive Flags Check                  node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_b    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_a    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_b    PASSED                                                                                                                          
Disk Health                        node_a    PASSED                                                                                                                                                                                    
DIMM Health                        node_a    PASSED                                                                                                                                                                                    
OS package name check              node_a    PASSED                                                                                                                                                                                    
Active System Alerts Check         node_a    PASSED                                                                                                                                                                                    
External Management Network        node_a    PASSED                                                                                                                                                                                    
Symmetric ICM Connection Check     node_a    PASSED                                                                                                                                                                                    
Time skew Check                    node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_b    PASSED                                                                                                                                                                                    
recovery partition image check     node_a    PASSED                                                                                                                                                                                    
recovery partition image check     node_b    PASSED                                                                                                                                                                                    
REST Authorization Service         node_a    PASSED                                                                                                                                                                                    
REST Authorization Service         node_b    PASSED                                                                                                                                                                                    
Fru FW Upgrade Flag Check          node_a    PASSED                                                                                                                                                                                    
Initiator Connectivity Redundancy  node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_b    PASSED                                                                                                                                                                                    
Pre-Upgrade Check                  node_a    WARNING                                                                                                                                                                                   
Pre-Upgrade Check                  node_b    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_a    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_b    PASSED                                                                                                                                                                                    
REST Configuration Service         node_a    PASSED                                                                                                                                                                                    
REST Data Service                  node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_b    PASSED                                                                                                                                                                                    
Component SN Check                 node_a    PASSED                                                                                                                                                                                    
Component SN Check                 node_b    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_a    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_b    PASSED                                                                                                                                                                                    
kms lockbox file check             node_a    PASSED                                                                                                                                                                                    
Internal File System               node_a    PASSED                                                                                                                                                                                    
Internal File System               node_b    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_a    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_b    PASSED                                                                                                                                                                                    
Internal Management Network        node_a    WARNING                                                                                                                                                                                   
SAS Expansion Enclosure Check      node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_b    PASSED                                                                                                                                                                                    
cyc_node space check               node_a    PASSED                                                                                                                                                                                    
cyc_node space check               node_b    PASSED                                                                                                                                                                                    

BBU Sensor Check                   node_a    FAILED     Mismatched part number detected on node A (KB#000196197)                                                                                                                       
BBU Sensor Check                   node_b    FAILED     Mismatched part number detected on node B (KB#000196197)
  
The user interface Hardware Component Internal View shows BBU Healthy for both nodes, but the BBU Part Number is different on each node.

BBU Hardware Component View Node A

BBU Hardware Component View Node B

svc_diag hardware check on both Node A and Node B show BBUs are OK.
Run the command against both nodes.
$ svc_diag list --hardware --sub_options fault_status
 
Hardware: ========== Fault Status register  ===========

Memory       dimm00: OK  | dimm01: OK  | dimm02: OK  | dimm03: OK  | dimm04: OK  | dimm05: OK  | dimm06: OK  | dimm07: OK  | 
             dimm08: OK  | dimm09: OK  | dimm10: OK  | dimm11: OK  | dimm12: OK  | dimm13: OK  | dimm14: OK  | dimm15: OK  | 
             dimm16: OK  | dimm17: OK  | dimm18: OK  | dimm19: OK  | dimm20: OK  | dimm21: OK  | dimm22: OK  | dimm23: OK  | 
EmbeddedDrve Drive00: OK  | Drive01: OK  | 
BackEndDrive Drive00: OK  | Drive01: OK  | Drive02: OK  | Drive03: OK  | Drive04: OK  | Drive05: OK  | Drive06: OK  | Drive07: OK  | 
             Drive08: OK  | Drive09: OK  | Drive10: OK  | Drive11: OK  | Drive12: OK  | Drive13: OK  | Drive14: OK  | Drive15: OK  | 
             Drive16: OK  | Drive17: OK  | Drive18: OK  | Drive19: OK  | Drive20: OK  | Drive21: OK  | Drive22: OK  | Drive23: OK  | 
             Drive24: OK  | 
I/O Module   iom00: OK  | iom01: OK  | 
Mezz         mez00: OK  | mez01: OK  | 
PSU          psu00: OK  | psu01: OK  | 

BBU          bbu00: OK  | bbu01: OK  | 
FAN          fan00: OK  | fan01: OK  | fan02: OK  | fan03: OK  | fan04: OK  | fan05: OK  | fan06: OK  | fan07: OK  | 
             fan08: OK  | fan09: OK  | fan10: OK  | fan11: OK  | fan12: OK  | fan13: OK  | 
Root I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
IO I2C       i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Other I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Mezz I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Drive I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
             i2c08: OK  | i2c09: OK  | i2c10: OK  | i2c11: OK  | i2c12: OK  | i2c13: OK  | i2c14: OK  | i2c15: OK  | 
             i2c16: OK  | i2c17: OK  | i2c18: OK  | i2c19: OK  | i2c20: OK  | i2c21: OK  | i2c22: OK  | i2c23: OK  | 
             i2c24: OK  | 

System       Bit  0  CPU Module: OK 
             Bit  1  Management Module: OK 
             Bit  2  Drive I/O Card 0: OK 
             Bit  3  eFlash : OK 
             Bit  4  Expansion Bay 0: OK 
             Bit  5  Enclosure: OK 
             Bit  6  CMI: OK 
             Bit  7  All Frus: OK 
             Bit  8  External: OK 
             Bit  9  Expansion Bay 1: OK 
             Bit 10  Drive I/O Card 1: OK                  

svc_diag shows different part numbers for BBU 0 and 1.
Run the command against both nodes.
$ svc_diag list --hardware --sub_options inventory |grep -A5 Battery
 
FRU Device Description : Battery0 (ID 9)
Board Mfg Date        : Tue Aug 18 00:00:00 2020
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPW4211500063  
Board Part Number     :
078-000-177-02  
--
FRU Device Description : Battery1 (ID 10)
Board Mfg Date        : Wed Dec 11 00:00:00 2019
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPV8200500140  
Board Part Number     :
078-000-168-02  
 

Cause

There is a problem in the latest system health check thin packages for PowerStoreOS 2.1.x and 3.x which incorrectly checks the BBU part number between the two nodes and fails if they are not the same.

All System Health Check packages since PowerStore-health_check-2.1.1.1-1736451 for PowerStoreOS 2.1.X are affected.
All System Health Check packages since PowerStore-health_check-3.0.0.0-1781415 for PowerStoreOS 3.X are affected.

PowerStore supports 11 different BBU part numbers and the system health check expects the PN of both BBUs to be the same, which may not be the case. Any of the below part numbers are valid and supported.
078-000-168-02
078-000-177-02
078-000-192-00
078-000-195-03
078-000-211-01
088-000-168-02
088-000-177-02
088-000-192-00
088-000-195-03
088-000-211-00
088-000-211-01

Resolution

If the BBUs are in a healthy state and the only error produced by running the system health check that thin package is "BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)," the error can be ignored and the NDU can be started.

This is fixed in a new release of the system health check thin packages under development.

Affected Products

PowerStore
Article Properties
Article Number: 000212653
Article Type: Solution
Last Modified: 29 Jul 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.