PowerStore: Pre upgrade health check (PUHC) to detect if the SdnasLastProcessedEventId number is large enough to cause an Out of Memory issue.

Summary: Pre upgrade health check to detect if the SdnasLastProcessedEventId number is large enough to cause an Out of Memory issue.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Pre upgrade health check (PUHC) fails with the following error: "Most recent NAS event id is too large. Please contact your service provider. KB#000227865 (off_release_sdnas_last_event_id_check)" Error code: 0xE10050060400

The health check is an off-release PUHC check that is contained in the Health Check thin package. See the Additional Info section of this article for information about the Health Check thin package.

As seen from the PowerStore Manager user interface (UI):
KB_000227865_figure1.png
 

Cause

Following an upgrade to PowerStoreOS version 4.0.0.0, in an environment where there are many NAS replication events, the last processed event ID becomes too large. In such case, an internal data structure may allocate a large amount of memory and cause the Control Path (CP) to encounter an Out of Memory (OOM) condition and restart. This CP OOM condition results in loss of PowerStore Manager (GUI) access. Furthermore, file replication sessions remain in a System Paused state until the issue is resolved. 

Note: This issue only impacts Unified systems with File replication.

Resolution

To resolve this issue, contact technical support for assistance. Reference KB# 000227865 for expedited attention and resolution.

Additional Information

Affected Products

PowerStore