PowerFlex 3.X Durante o NDU, um SDS trava durante a execução da função mgStorageRegion_CopyFromBuffer

Summary: SDS travando na função mgStorageRegion_CopyFromBuffer

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 - Atualização de 3.0 para 3.6

 - SDS saindo do modo de manutenção instantânea (IMM)  

- A soma de verificação a bordo está ativada.  

O SDS trava com a seguinte pane: 

2022/12/20 10:22:18.543129 Panic in file /data/build/workspace/ScaleIO-Common-Job/src/tgt/storage/mg_impl/mg_storage_region.c, line 4188, function mgStorageRegion_CopyFromBuffer, PID 13108.Panic Expression !(bufferSizeInBytes != ((sizeInLbs) * (512))) PANIC_ID_tgt_1517847817759.
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mosDbg_PanicPrepare+0x13a) [0x93ab8a]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mgStorageRegion_CopyFromBuffer+0x1a7) [0x810477]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mgStorageRegion_CopyFromCachedBuffer+0x33) [0x810873]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(storageRegion_CopyFromCachedBuffer+0xde) [0x4d3f3e]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(mgStorageRegion_ReadFromSyncBuf+0x45) [0x4d4a85]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidComb_ReadFromRemoteUntilEntireRegionIsAcquired+0x451) [0x74e021]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidComb_ReadVolumeFromRemote+0x3ae) [0x74e8ee]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidReverseRebuild_LoopAndCopy+0x140f) [0x75518f]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidReverseRebuild_Start+0xb56) [0x7583c6]
/opt/emc/scaleio/sds/bin/sds-3.6.400.107(raidSyncPool_StartJob+0x375) [0x5e3145]

O recurso de soma de verificação em trânsito está ativado no(s) pool(s) de armazenamento:

Storage Pool durpsdsc7p8pool1 (Id: 469b0f6800000007) has 7 volumes and 236.9 TB (242550 GB) free net capacity. 2.5 PB (2524 TB) volume allocation limit.
...
Inflight Checksum: Enabled
...

 

Impacto

O SDS está travando e não consegue sair do IMM. Se, durante um upgrade, o upgrade não poderá continuar.

Cause

Devido a ser um caso de borda e ao fato de ser uma versão muito desatualizada que não é mais suportada, é essencial implementar a solução temporária descrita na seção Resolução abaixo.

Resolution

Desative a soma de verificação em trânsito no pool de armazenamento para o qual o SDS contribui:

1) Consulte todos os SDSs para obter o nome/ID do SDS:

[root@nestedsvm2 ~]# scli --query_all_sds
Query-all-SDS returned 3 SDS nodes.

Protection Domain 8eeacbf900000000 Name: pd1
SDS ID: ab471ceb00000002 Name: svm103 State: Connected, Joined IP: 15.15.15.103 Port: 7072 Version: 3.6.500
SDS ID: ab471cea00000001 Name: svm102 State: Connected, Joined IP: 15.15.15.102 Port: 7072 Version: 3.6.500
SDS ID: ab471ce800000000 Name: svm101 State: Connected, Joined IP: 15.15.15.101 Port: 7072 Version: 3.6.500

2) Consulte o SDS por nome/ID e procure "Storage Pool: ":

 Nota: o(s) pool(s) de armazenamento para o qual ele contribui com dispositivos; Nesse caso, há apenas um, que é o nome do pool de armazenamento "SP1".

[root@nestedsvm2 ~]# scli --query_sds --sds_id ab471ceb00000002 | grep -i 'storage pool:'
         1: Storage Pool: sp1  inflight requests factor: 115, inflight bandwidth factor 115
                Storage Pool: sp1, Capacity: 198 GB, State: Normal
                Storage Pool: sp1, Capacity: 98 GB, State: Normal
                Storage Pool: sp1, Capacity: 98 GB, State: Normal

3) Consulte o pool de armazenamento e procure "Inflight Checksum: ":

[root@nestedsvm2 ~]# scli --query_storage_pool --storage_pool_name sp1 --protection_domain_name pd1 | grep -i 'Inflight checksum'
        Inflight Checksum: Enabled

3.a) Para desativar a soma de verificação a bordo, ela pode ser feita usando scli ou no Servidor de Apresentação. Para desativá-lo usando scli, execute o comando abaixo:

[root@nestedsvm2 ~]# scli --set_checksum_mode --protection_domain_name pd1 --storage_pool_name sp1 --disable_inflight_checksum
Checksum mode modified successfully

3.b) No Servidor de apresentação, navegue até Storage Pools > , selecione Storage Pool > Modify > General > , desmarque "Enable Inflight Checksum" > Apply.  

 

 Versões afetadas

PowerFlex 3.5.x

 PowerFlex 3.6.x

Affected Products

PowerFlex appliance connectivity

Products

PowerFlex rack, VxFlex Ready Nodes, PowerFlex custom node, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625 , PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000225317
Article Type: Solution
Last Modified: 03 Feb 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.