『PowerEdge: MX760cスレッドの取り付け後のMX7000ファンの警告

Summary: POS(APOS)後にMX760cスレッドをMX7000シャーシに取り付けた後のOpen Manage Enterprise - Modular(OME-M)のファン警告メッセージ。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

これはファン警告メッセージの例ですが、シャーシに搭載されているすべてのファンに表示されます。
=====================================================
Front fan 1 requires attention for optimal performance.
Desc: A device in the chassis requires a fan type that does not match the configuration of the fan identified in the message. Some devices may experience varied performance and possible thermal errors depending on the configuration, workload, and environment.
Action: Replace the fan with a Gen2 fan during the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 User's Guide available on the support site.
=====================================================

Cause

最適化されたシャーシを必要とするMX760Cスレッドを搭載したMX7000の熱および電源の最適化要件は、スレッドを購入して取り付ける前にチェックされませんでした。

Resolution

販売後にMX760Cスレッドを取り付ける場合は、MX7000シャーシで次のアップグレードを実行する必要があります。
  • MX7000ゴールド グレード(ハードウェア バージョン2、Gen2)ファン(カスタマー キットPN: H2YC5/SKU: SKU 750-ADWNMX760cのMXソリューション注文に含まれる)
  • OpenManage Enterprise - Modular(OME-M)FWバージョン2.00.00
  • iDRACバージョン05.10.25/06.10.05
  • EIPT(Enterprise Infrastructure Planning Tool )
メモ: システム構成を選択またはアップグレードする際に、最適な電力使用率を確保するには、使用可能なエンタープライズ インフラストラクチャ プランニング ツールを使用して、システムの電力消費量を確認します。

メモ: 熱最適化スレッドからスロットへの割り当てを生成するには、EIPTツールでMX構成を入力し、[ 最適化 ]をクリックします。

詳細については、 Dellサポート製品ページ にある 『 MX760c設置およびサービス マニュアル 』を参照してください。