PowerEdge:安裝 MX760c SLED 後,MX7000 風扇警告

Summary: 在銷售點 (APOS) 將 MX760c SLED 安裝至 MX7000 主機殼後,Open Manage Enterprise - 模組化 (OME-M) 中的風扇警告訊息。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

這是風扇警告訊息的範例,但在主機殼隨附的所有風扇上都會出現。
=====================================================
Front fan 1 requires attention for optimal performance.
Desc: A device in the chassis requires a fan type that does not match the configuration of the fan identified in the message. Some devices may experience varied performance and possible thermal errors depending on the configuration, workload, and environment.
Action: Replace the fan with a Gen2 fan during the next scheduled service. Dell recommends as soon as possible for optimal performance. For more information about recommended fan configurations, see the MX7000 User's Guide available on the support site.
=====================================================

Cause

在購買和安裝 SLED 之前,未檢查需要優化主機殼的 MX7000 搭配 MX760C SLED 的散熱和電源優化需求。

Resolution

在銷售點之後安裝 MX760C SLED 時,必須先升級 MX7000 主機殼:
  • MX7000 黃金級 (硬體版本 2,Gen2) 風扇 (客戶套件 PN:H2YC5/SKU:SKU 750-ADWN;隨附 MX760c 的 MX 解決方案訂單中包含)
  • Open Manage Enterprise - Modular (OME-M) FW 2.00.00 版
  • iDRAC 版本 05.10.25/06.10.05
  • 企業基礎架構規劃工具 (EIPT)
注意:選取或升級系統組態時,為確保最佳電源使用率,請使用可用的企業基礎架構規劃工具來確認系統耗電量。

注意:若要產生散熱優化的運算模組對插槽指派,請在 EIPT 工具中輸入 MX 組態,然後按一下 Optimize。

請參閱 Dell 支援產品頁面上提供的 MX760c 安裝與維修手冊 ,以取得完整的資訊。