PowerStore: XtremIO läggs till när fjärrsystemet misslyckas med sys_not_found
Summary: Tillägg av en Dell EMC XtremIO till PowerStore som ett fjärrsystem för dataimport misslyckas med felet: Det går inte att hämta XtremIO-klusterinformation [sys_not_found].
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Tillägg av XtremIO som fjärrsystem för dataimport misslyckas med felet sys_not_found.
Motsvarande felmeddelande i XtremIO xms.log visar en lyckad inloggning med samma felmeddelande som vidarebefordras till PowerStore:
Mar 25 12:52:33 xxxxx-A control-path[95525]: xx [DATAMOBILITY] [INFO] [com.emc.cyclone.contexts.datamobility.services.remotesystem.CreateRemoteSystemAS|vert.x-eventloop-thread-0] [xx] Creating remote system: {
"create_remote_peer" : false,
"management_address" : "",
"name" : "",
"description" : "",
"remote_username" : "",
"type" : "XtremIO",
"discovery_chap_mode" : "Disabled",
"session_chap_mode" : "Disabled",
"iscsi_addresses" : [ "" ],
"data_network_latency" : "Low",
"_id" : "c5806950-7bdb-4d1b-a710-f518f6e09fc8",
"command_type" : "com.emc.cyclone.contexts.datamobility.commands.remotesystem.CreateRemoteSystemCommand",
"command_class_name" : "com.emc.cyclone.contexts.datamobility.commands.remotesystem.CreateRemoteSystemCommand",
"command_metadata" : {
"REST-Request-ID" : "723fcf20-6aa5-4bb0-b1e3-b97cf2252e29",
"httpQueryParams" : { },
"isAutoAcknowledge" : true,
"persisted" : true,
"isDupe" : false
},
"routing_metadata" : {
"source_location" : "CLUSTER_MASTER"
},
"executionLocation" : "CLUSTER_MASTER",
"command_state" : "RUNNING",
"priority" : "DEFAULT",
"is_cancellable" : false,
"is_async" : false,
"customauth" : "",
"userRole" : "Administrator",
"client_address" : "",
"user_name" : "",
"root_id" : "c5806950-7bdb-4d1b-a710-f518f6e09fc8",
"command_description" : "...",
"is_restartable" : true,
"is_encrypted" : true,
"is_internal" : false,
"resource_type" : "remote_system",
"canQueue" : true,
"retention_period" : 0,
"resource_action" : "create",
"work_unit_id" : "972e5c12-9920-44d6-822d-daad0a05c85c"
}
...
Mar 25 12:52:34 xxxxx-A control-path[95525]: [ERROR] [com.emc.cyclone.contexts.destinationcyclone.infrastructure.adapters.storage.xio.impl.XtremIOAdapterImpl|vert.x-eventloop-thread-2] [] XtremIO REST error response for REST API: /api/json/v3/types/clusters?cluster-name=&full=1∝=sys-psnt-serial-number∝=sys-sw-version∝=sys-state∝=sys-id∝=hardware-platform∝=obj-severity∝=chap-discovery-mode∝=chap-authentication-mode and XtremIO: xx.xx.xx.xx : io.vertx.ext.web.client.impl.HttpResponseImpl@5166a6ff
Mar 25 12:52:34 xxxxx-A control-path[95525]: [ERROR] [com.emc.cyclone.contexts.destinationcyclone.infrastructure.adapters.storage.xio.impl.XtremIOAdapterImpl|vert.x-eventloop-thread-2] [] getSystemDetails failed for XtremIO:
Unable to get XtremIO cluster details [sys_not_found].
at com.emc.cyclone.contexts.destinationcyclone.infrastructure.adapters.storage.xio.impl.XtremIOAdapterImpl.createAdapterException(XtremIOAdapterImpl.java:1350)
at com.emc.cyclone.contexts.destinationcyclone.infrastructure.adapters.storage.xio.impl.XtremIOAdapterImpl.lambda$getSystemDetails$13(XtremIOAdapterImpl.java:340)
at io.reactivex.internal.operators.single.SingleResumeNext$ResumeMainSingleObserver.onError(SingleResumeNext.java:73)
at io.reactivex.internal.operators.single.SingleDoOnSuccess$DoOnSuccess.onError(SingleDoOnSuccess.java:65)
at io.reactivex.internal.operators.single.SingleMap$MapSingleObserver.onError(SingleMap.java:69)
...
Motsvarande felmeddelande i XtremIO xms.log visar en lyckad inloggning med samma felmeddelande som vidarebefordras till PowerStore:
2022-03-25 12:53:34 - XmsLogger[13466:fd60::RSTe19a2a:RSTc0d68c] - INFO - context::auth:172 - User authentication successful. user: , IP:
2022-03-25 12:53:34 - XmsLogger[13472:47a0::RSTa17440:RSTbf36d3] - INFO - context::auth:172 - User authentication successful. user: , IP:
2022-03-25 12:53:34 - XmsLogger[13472:47a0::RSTa17440:RSTbf36d3] - ERROR - context::process_wrapper:285 - Caught exception in query process:
Traceback (most recent call last):
File "xms/context.py", line 283, in process_wrapper
File "xms/context.py", line 265, in actual_command
File "xms/common_server.py", line 151, in execute_command
File "xms/executor.py", line 825, in query
File "xms/executor.py", line 852, in _query
File "xms/models/mom/object_id.py", line 571, in get_system
RpcFault:
2022-03-25 12:53:34 - XmsLogger[3746:99e6::RSTa17440] - ERROR - rest_server::handle_error:375 - rest_server error: Traceback (most recent call last):
File "/xtremapp/xms/python27_env/lib/python2.7/site-packages/twisted/internet/defer.py", line 653, in _runCallbacks
current.result = callback(current.result, *args, **kw)
File "xms/executor.py", line 423, in command_cb_eb
RpcFault: 2022-03-25 12:53:34,872 - XmsLogger[13480:6b71::JESac59f1] - INFO - esrsve_tasks::run:174 - Sent SYR using MFT
Cause
Detta inträffar om namnet som anges i guiden för att lägga till fjärrsystem i PowerStore inte matchar det namn som konfigurerats på XtremIO-systemet.
Resolution
Använd det verkliga XtremIO-namnet i guiden.
Du hittar XtremIO-klusternamnet:
Du hittar XtremIO-klusternamnet:
- Använda XtremIO-webbgränssnittet, under Inventory > Clusters
- Använda CLI med kommandot: xmcli (tech)> show-clusters
Additional Information
Importkrav och begränsningar visas i dokumentet Importing External Storage to PowerStore på https://www.dell.com/powerstoredocs.
Om fjärrsystemet XtremIO rapporterar en fullständig dataanslutningsförlust efter att du har lagt till den i PowerStore, och du kan pinga iSCSI-portarna, kontrollera att anslutningen på både hanterings- och lagringsnätverket mellan XtremIO och PowerStore fungerar och att inloggningsuppgifterna är giltiga.
PowerStore använder det replikeringsmärkta nätverket för importer.
Om du måste ändra replikeringstaggen till ett annat nätverk tar du bort XtremIO-fjärrsystemet, ändrar replikeringstaggen och lägger sedan till det igen.
Om fjärrsystemet XtremIO rapporterar en fullständig dataanslutningsförlust efter att du har lagt till den i PowerStore, och du kan pinga iSCSI-portarna, kontrollera att anslutningen på både hanterings- och lagringsnätverket mellan XtremIO och PowerStore fungerar och att inloggningsuppgifterna är giltiga.
PowerStore använder det replikeringsmärkta nätverket för importer.
Om du måste ändra replikeringstaggen till ett annat nätverk tar du bort XtremIO-fjärrsystemet, ändrar replikeringstaggen och lägger sedan till det igen.
Affected Products
PowerStore 1000X, PowerStore 1000T, PowerStore 3000X, PowerStore 3000T, PowerStore 5000X, PowerStore 5000T, PowerStore 500T, PowerStore 7000X, PowerStore 7000T, PowerStore 9000TProducts
PowerStore 9000XArticle Properties
Article Number: 000198206
Article Type: Solution
Last Modified: 11 Apr 2022
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.