Connectrix MDS 9000 Series: Error: "Command disallowed in current zoning mode"

Summary: "Error: Command is disallowed in current zoning mode" is received when running command "zone commit vsan X."

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The new zone is configured in VSAN X.

While trying to run zone commit vsan X, the following error triggered:
Error: Command is disallowed in current zoning mode

Cause

VSAN X zoning mode was basic mode and not enhanced mode.

Resolution

It is not necessary to run the zone commit vsan X command in basic zoning mode.

Affected Products

Connectrix MDS-9148S

Products

Connectrix MDS-9148S, Connectrix MDS-Series Firmware, Connectrix MDS-Series Hardware
Article Properties
Article Number: 000060418
Article Type: Solution
Last Modified: 08 Oct 2025
Version:  3