Connectrix MDS 9000 Series: Error: "Command disallowed in current zoning mode"
Summary: "Error: Command is disallowed in current zoning mode" is received when running command "zone commit vsan X."
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The new zone is configured in VSAN X.
While trying to run
While trying to run
zone commit vsan X, the following error triggered:
Error: Command is disallowed in current zoning mode
Cause
VSAN X zoning mode was basic mode and not enhanced mode.
Resolution
It is not necessary to run the
zone commit vsan X command in basic zoning mode.Affected Products
Connectrix MDS-9148SProducts
Connectrix MDS-9148S, Connectrix MDS-Series Firmware, Connectrix MDS-Series HardwareArticle Properties
Article Number: 000060418
Article Type: Solution
Last Modified: 08 Oct 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.