VNX OE: How to work around the PCI components mismatch error during failover

Summary: This article explains how to work around the PCI components mismatch error during failover.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

One of the I/O modules on slot_2 was faulted and cannot be loaded during data mover reboot. In order to restore access for end users before replacing the I/O module, failover the server_2 to slot_3.

However, there was a PCI components mismatch error due to the faulted I/O module.

[nasadmin@cs0 /]$ server_standby server_2 -activate mover
server_2 :
Error 12032: server_2 : PCI components mismatch: blade hardware on standby server_3 does not match exactly the primary blade hardware.

To work around this issue, power off slot_2 and failover again.

[nasadmin@cs0 /]$ /nas/sbin/t2reset pwroff -s 2
[nasadmin@cs0 /]$ server_standby server_2 -activate mover
server_2 :
 server_2 : going offline
 server_3 : going active
 replace in progress ...done
 failover activity complete
 commit  in progress (not interruptible)...done
 
server_2 : renamed as server_2.faulted.server_3
server_3 : renamed as server_2
...

Additional Information

This workaround only applies to this specific situation.