Connectrix B-Series: Firmware download failed on standby CP-Failed to validate firmware signature

Summary: Firmware download failed on standby CP - Failed to validate firmware signature. (0x3e)

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Firmware upgrade.

The following error message is encountered when upgrading FOS on a chassis based switch. 
Firmware download failed on standby CP - Failed to validate firmware signature. (0x3e)
RAS logs:
[SULB-1011], 374, SLOT 5 | CHASSIS, INFO,Firmwaredownload command failed. Failed to validate firmware signature

Cause

unknown

Resolution

  • Ensure that there is an Ethernet connection to both the Active and Standby CP management ports.
  • Ensure that the IP addresses for both CPs and the chassis are all in the same subnet.
  • Ensure also that you can ping the Active IP address, Standby IP address, and Chassis IP address.

Affected Products

Connectrix ED-48000B, Connectrix ED-DCX6-4B, Connectrix ED-DCX6-8B, Connectrix ED-DCX8510-4B, Connectrix ED-DCX8510-8B