Connectrix B-Series: Firmware download failed on standby CP-Failed to validate firmware signature
Summary: Firmware download failed on standby CP - Failed to validate firmware signature. (0x3e)
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Firmware upgrade.
The following error message is encountered when upgrading FOS on a chassis based switch.
The following error message is encountered when upgrading FOS on a chassis based switch.
Firmware download failed on standby CP - Failed to validate firmware signature. (0x3e)RAS logs:
[SULB-1011], 374, SLOT 5 | CHASSIS, INFO,Firmwaredownload command failed. Failed to validate firmware signature
Cause
unknown
Resolution
- Ensure that there is an Ethernet connection to both the Active and Standby CP management ports.
- Ensure that the IP addresses for both CPs and the chassis are all in the same subnet.
- Ensure also that you can ping the Active IP address, Standby IP address, and Chassis IP address.
Affected Products
Connectrix ED-48000B, Connectrix ED-DCX6-4B, Connectrix ED-DCX6-8B, Connectrix ED-DCX8510-4B, Connectrix ED-DCX8510-8BArticle Properties