PowerProtect: O backup do OpenShift falha com o erro "cproxy" já existe
Summary: O trabalho de proteção falha devido ao erro "cproxy already exists".
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
O trabalho de proteção do PowerProtect Data Manager apresenta falha com uma mensagem de erro semelhante à seguinte:
Error: Unable to backup PersistentVolumeClaims. PVC backup returned with an error: Unable to backup PVC 'XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXXX-1'. Unable to create Pod 'XXXXXXXXX-XXXXXXXXXX-YYYY-MM-DD-HH-MM-SS-XXXXXXXXX-XXXXXXXXXX-XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXX-YYYY-MM-DD-HH-MM-SS-cproxy': pods "XXXXXXXXX-XXXXXXXXXX-YYYY-MM-DD-HH-MM-SS-XXXXXXXXX-XXXXXXXXXX-XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXX-YYYY-MM-DD-HH-MM-SS-cproxy" already exists Unable to backup PVC 'XXX-XXXXXXXXXXXX-XXXXX-XXXXXXXXXXXX-XXXX-1': Unable to create pod in safeguard limit of 10 minutes.
Esse problema ocorre quando as seguintes condições são atendidas:
- Há vários PVCs que têm os mesmos primeiros 40 caracteres em seus nomes.
- O processamento paralelo de vários PVCs está habilitado.
- O PowerProtect Data Manager versão 19.17.0-10 e versões anteriores está em uso.
Cause
Este é um defeito de software.
Resolution
Esse problema foi resolvido no PowerProtect Data Manager versão 19.17.0-18.