GDDR: When running script GDDRPA23 the secondary site was not displayed in the banner correctly

Summary: GDDR: When running script GDDRPA23 the secondary site was not displayed in the banner correctly

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Script GDDRPA23, in a STAR with AutoSwap configuration, was automatically submitted by the GDDR Event Manager (EVM) to resume ConGroup from DC2 to DC1 and the secondary site was not displayed in the banner correctly.  An '*' was displayed instead of DC1.

09.35.23 JOB31056 +GDDO041I GDDR Confirmation ===> 799
799 **************************************************
799 *                                                *
799 * Please Confirm Resume ConGroup                 *
799 *                                                *
799 *                                                *
799 *                                                *
799 * Secondary DASD Site: *                         *
799 *                                                *
799 **************************************************
09.35.23 JOB31056 +GDDO042A Please Confirm Resume ConGroup (Yes/No):
The script was automatically submitted by the EVM.
01MAR 09:00:05 CONSOLE  $HASP100 GDDRPA23 ON INTRDR      GDDR-JOB              FROM STCnnnnn GDDREVM
The issue occurs if the script is submitted manually using the
F GDDRMAIN,SCRIPT,GDDRPA23 
command.

Cause

This is a software issue.

Resolution

Permanent Fix:
  • For GDDR 6.0, PTF GD60020 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.

Affected Products

Geographically Dispersed Disaster Restart (GDDR)