BigSwitch ZTD does not complete when using OS10 as p-network switch.
Summary: The DellEMC OS10 based switch as the p-network switch for a BigSwitch Fabric. The BCF or BMF switches may not fully boot and connect to the controller in a switchlight operating system. The boot stops at the ZTD discovery. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The controller and switches can ping each other IPv6 link local address. However, the process still does not fully complete. This can occur when the IPv6 packet crosses between switches such as the topology below. 
Cause
The MLD snooping will not forward the ipv6 ND packets across the port-channel between switches.
Resolution
To resolve this issue the following commands globally on both switches:
OS10(config)# no ip igmp snooping enable
OS10(config)# no ipv6 mld snooping enable
Dell EMC OS10 has IGMP snooping and IPv6 MLD snooping enabled by default. This can result in the IPv6 discovery frames from Switchlight to the controller to be intercepted between switches.
Affected Products
PowerSwitch S3048-ON, Dell EMC BSN Controller Node, Dell EMC BSN Controller VM, PowerSwitch S4048T-ON, PowerSwitch S4148F-ON/S4148T-ON/S4148FE-ON, PowerSwitch Z9332F-ON, SmartFabric OS10 SoftwareArticle Properties
Article Number: 000132960
Article Type: Solution
Last Modified: 11 Oct 2023
Version: 5