Feilsøkingsveiledning for fysiske vSAN-disker

Summary: Dette er en generell feilsøkingsveiledning som hjelper deg med å identifisere om det er et problem med en fysisk disk i vSAN-klynger.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Instructions

Kontrollere status for fysisk vSAN fra webgrensesnittet:

Koble til vCenter Server Web Client, og kontroller diskstatusen fra:
 
Lager > Vert og klynger vSAN-klynge > Konfigurere > vSAN Disk Management Bilde 1: vSAN Disk Management-visning Velg den berørte verten, og utvid deretter visningsdiskdelen:Bilde 2: vSAN > Disk Group-visning > Visning av vSAN Disk Management
Gruppevisning av vSAN-disk


Her kan du kontrollere om en disk oppdages som:




 
Usunn
Umontert
0 kapasitet
Permanent diskfeil
Disk ned
disk fraværende
 
Se også etter diskrelaterte alarmer som utløses fra vSAN Skyline Health-delen:
 
Lager > Vert og klynger > vSAN Cluster > Monitor > vSAN > Skyline Health > Fysisk disk

Bilde 3: Skyline Health-visning
Skyline Health-visning
Her kan du kontrollere om noen av følgende alarmer utløses:
 
Forestående permanent diskfeil, data blir evakuert (Helsetilstand - Gul).
Forestående permanent diskfeil, dataevakuering mislyktes på grunn av utilstrekkelige ressurser (Helsetilstand - Rød).
Forestående permanent diskfeil, dataevakuering mislyktes på grunn av utilgjengelige objekter (Helsetilstand - Rød).
Forestående permanent diskfeil, evakuering av data er fullført (Helsetilstand – gul)
 
Du kan også kontrollere diskstatus fra listen over lagringsenheter til den berørte verten:
 
Lager > Vert og klynger vSAN-klynge > berørt vSAN ESXi-vert >> Konfigurere > lagringslagringsenheter >

Bilde 4: Visning
Visning av vertslagringsenheter
av vertslagringsenheter Her kan du kontrollere om diskstatusen er:
 
0 Kapasitet
Disk fraværende
disk umontert
 
Bekreft om det er en Resync skjer:
 
Lager > Vert og klynger > vSAN Cluster > Monitor > vSAN > Resyncing Objects:Bilde 5:

Visning av nye synkroniseringsobjekter
Visning av nye synkroniseringsobjekter
MERK: Ny synkronisering kan indikere at data evakueres fra en berørt disk eller diskgruppe. Ytterligere undersøkelser er nødvendig for å avgjøre om den berørte disken er klar til å fjernes eller erstattes.

 
Bekreft statusen til vSAN Objects:
 
Lager > Vert og klynger vSAN Cluster > Monitor > vSAN Skyline Health > Data vSAN > object health Bilde 6>: vSAN-objekttilstandsvisning >


vSAN-objekttilstandsvisning
MERK: Det er viktig å verifisere at det ikke er noen utilgjengelige objekter. Objekt utilgjengelig betyr "alle kopier av objektet mangler." Hvis du tar ut eller bytter ut en disk som kan forårsake DL.

 
Det neste trinnet er å samle inn mer informasjon om problemet via CLI og kontrollere loggene: Kontrollere status for fysisk vSAN fra CLI:Connect over SSH til den berørte verten, og kjøre følgende kommandoer:




 
vdq -qH
Sjekk parameteren "IsPDL" (permanent enhetstap). Hvis det er lik 1, går disken tapt.
 
Eksempel:
 
DiskResults:
 DiskResult[0]:
 Name: naa.600508b1001c4b820b4d80f9f8acfa95
 VSANUUID: 5294bbd8-67c4-c545-3952-7711e365f7fa
 State: In-use for VSAN
 ChecksumSupport: 0
 Reason: Non-local disk
 IsSSD?: 0
IsCapacityFlash?: 0
 IsPDL?: 0
 <<truncated>>
 DiskResult[18]:
 Name:
 VSANUUID: 5227c17e-ec64-de76-c10e-c272102beba7
 State: In-use for VSAN
 ChecksumSupport: 0
 Reason: None
 IsSSD?: 0
IsCapacityFlash?: 0
 IsPDL?: 1
 
vdq -iH
Kontroller om det mangler en disk fra diskgruppen.
 
Eksempel:
 
Mappings:
DiskMapping[0]:
SSD: naa.58ce38ee2016ffe5
MD: naa.5002538a4819e3e0
 
DiskMapping[2]:
SSD: naa.58ce38ee2016fe55
MD: naa.5002538a48199ca0
MD: naa.5002538a48199e20
MD: naa.5002538a48199e00
 
esxcli vsan storage list
Sjekk parameteren "In CMMDS". Hvis falsk, går kommunikasjonen tapt til disken.
 
Eksempel:
 
Device: Unknown
Display Name: Unknown
Is SSD: false
VSAN UUID: 529cadbc-acd1-b588-8643-68336d5512d6
VSAN Disk Group UUID:
VSAN Disk Group Name:
Used by this host: false
In CMMDS: false
On-disk format version: <Unknown>
Deduplication: false
Compression: false
Checksum:
Checksum OK: false
Is Capacity Tier: false
 
for i in `esxcli  storage core device list | grep ^naa` ; do echo $i; esxcli storage core device smart get -d $i; done.
Se etter lese-/skrivefeil med Smart Get-kommandoen.
 
Eksempel:
 
naa.55cd2e404c1f35a1
Parameter                   Value  Threshold  Worst  Raw
--------------------------  -----  ---------  -----  ---
Health Status               OK     N/A        N/A    N/A
Media Wearout Indicator     100    0          100    86
Read Error Count            130    39         130    133
Power-on Hours              100    0          100    110
Power Cycle Count           100    0          100    106
Drive Temperature           100    0          100    26
Uncorrectable Sector Count  100    0          100    0
naa.55cd2e404c1f35a5
Parameter                   Value  Threshold  Worst  Raw
--------------------------  -----  ---------  -----  ---
Health Status               OK     N/A        N/A    N/A
Media Wearout Indicator     100    0          100    10
Read Error Count            130    39         130    53
Power-on Hours              100    0          100    110
Power Cycle Count           100    0          100    106
Drive Temperature           100    0          100    27
Uncorrectable Sector Count  100    0          100    0
 
esxcli vsan storage list | grep "VSAN Disk Group UUID:" | sort | uniq -c
Se etter tilgjengelige diskgrupper.
 
Eksempel:
 
      2    VSAN Disk Group UUID: 5203424c-ee56-497d-75d1-fcf73ae997cb
      2    VSAN Disk Group UUID: 52af8e5c-77d1-b552-3310-ec5fef09edf4
 
while true;do echo " ****************************************** "; echo "" > /tmp/resyncStats.txt ;cmmds-tool find -t DOM_OBJECT -f json |grep uuid |awk -F \" '{print $4}' |while read i;do pendingResync=$(cmmds-tool  find -t DOM_OBJECT -f json -u $i|grep -o "\"bytesToSync\": [0-9]*,"|awk -F " |," '{sum+=$2} END{print sum / 1024 / 1024 / 1024;}');if [ ${#pendingResync} -ne 1 ]; then echo "$i: $pendingResync GiB";fi;done |tee -a /tmp/resyncStats.txt;total=$(cat /tmp/resyncStats.txt |awk '{sum+=$2} END{print sum}');echo "Total: $total GiB" |tee -aa /tmp/resyncStats.txt;total=$(cat /tmp/resyncStats.txt  |grep Total);totalObj=$(cat /tmp/resyncStats.txt|grep -vE " 0 GiB|Total"|wc -l);echo "`date +%Y-%m-%dT%H:%M:%SZ` $total ($totalObj objects)" >> /tmp/totalHistory.txt; echo `date `; sleep 60; done
Sjekk om det er pågående eller stopper resynkroniseringsoperasjoner.
 
Eksempel:
 
Total: 0 GiB
Mon Feb 13 17:32:06 UTC 2023

Trykk CTRL+C for å stoppe kommandoen.
 
cmmds-tool find -f python | grep CONFIG_STATUS -B 4 -A 6 | grep 'uuid\|content' | grep -o 'state\\\":\ [0-9]*' | sort | uniq -c
Kontroller tilstanden til komponentene.
 
Sunn -- tilstand 7
Utilgjengelig -- tilstand 13
Fraværende eller degradert -- tilstand 15
 
Eksempel:
 
    425 state\": 7
 
Slik identifiserer du hvor den defekte SSD eller harddisken er plassert over CLI:
 
Liste over alle tilgjengelige enheter:
esxcli storage core device list | grep "naa" | awk '{print $1}' | grep "naa"

Eksempel:
 
naa.5000c500852df8d3
naa.55cd2e404c1f35a1
naa.55cd2e404c1f35a5
naa.5000c500852dd5e7

Kontroller plasseringen ved hjelp av hver disk naa fra listen:
esxcli storage core device physical get -d
 
Eksempel:
 
esxcli storage core device physical get -d naa.5000c500852df8d3
esxcli storage core device physical get -d naa.55cd2e404c1f35a1
esxcli storage core device physical get -d naa.55cd2e404c1f35a5
esxcli storage core device physical get -d naa.5000c500852dd5e7
 
   Physical Location: enclosure 65535 slot 0
   Physical Location: enclosure 65535 slot 1
   Physical Location: enclosure 65535 slot 2
   Physical Location: enclosure 65535 slot 3

Slik identifiserer du den defekte HARDDISKEN eller SSD-en hvis enhetsnavnet mangler:

Det er mulig at den defekte disken ikke oppdages og ikke kan identifiseres ved hjelp av tilsvarende naa. I dette scenariet er det nødvendig å finne alle disker, og den som ikke er fysisk plassert, vil være den som mislyktes.

Her er et skript som kan brukes til å utføre oppgaven litt raskere:
echo "=============Physical disks placement=============="
echo ""
esxcli storage core device list | grep "naa" | awk '{print $1}' | grep "naa" | while read in; do
echo "$in"
esxcli storage core device physical get -d "$in"
sleep 1
echo "===================================================="
done

vSAN relevante logger for lagringsrelaterte problemer:
 
/var/log/vmkernel.log
Problemer med å lese og skrive til vSAN-disker, vSAN-verthjerteslag, PDL-er, SCSI-sensorkoder og I/O-forespørsler (leser/skriver) og informasjon om klyngemedlemskap.
 
Eksempel:
 
2021-06-22T12:02:08.408Z cpu30:1001397101)ScsiDeviceIO: PsaScsiDeviceTimeoutHandlerFn:12834: TaskMgmt op to cancel IO succeeded for device naa.55cd2e404b7736d0 and the IO did not complete. WorldId 0, Cmd 0x28, CmdSN = 0x428.Cancelling of IO will be
2021-06-22T12:02:08.408Z cpu30:1001397101)retried.

/var/log/vobd.log
Rapporter om disktilstand, tapte disker (PDL-er) for permanente enheter), diskventetid og rapporter om når en vert går inn i og avslutter vedlikeholdsmodus.
 
Eksempel:
 
2022-05-31T11:42:46.065Z: [vSANCorrelator] 10605891965954us: [vob.vsan.lsom.devicerepair] vSAN device 521a74ce-c980-c16c-ff3d-38a036233daf is being repaired due to I/O failures, and will be out of service until the repair is complete. If the device is part of a dedup disk group, the entire disk group will be out of service until the repair is complete.
2022-05-31T11:42:46.065Z: [vSANCorrelator] 10606062774178us: [esx.problem.vob.vsan.lsom.devicerepair] Device 521a74ce-c980-c16c-ff3d-38a036233daf is in offline state and is getting repaired

/var/log/vsandevicemonitord.log
Det hjelper deg med å finne ut om disken ble merket som usunn på grunn av overdreven overbelastning av loggen eller ventetider på I/O.
 
Eksempel:
 
INFO vsandevicemonitord WARNING - WRITE Average Latency on VSAN device naa.50000xxxxxxxx has exceeded threshold value 2000000 us 2 times.
INFO vsandevicemonitord Tier 2 (naa.50000xxxxxxxx) as unhealthy

Article Properties


Affected Product

VMware ESXi 7.x, VMware VSAN

Product

VMware, VMware ESXi 6.7.X

Last Published Date

12 Feb 2024

Version

3

Article Type