Guia de solução de problemas do disco físico do vSAN

Summary: Este é um guia geral de solução de problemas para ajudar a identificar se há um problema com um disco físico em clusters do vSAN.

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Instructions

Verificando o status do disco físico do vSAN na IU da Web:

Conecte-se ao vCenter Server Web Client e verifique o status do disco em:
 
Inventário > Host e clusters > Cluster do vSAN Configurar > o gerenciamento de discos do vSAN Figura 1: exibição do vSAN Disk Management Selecione o host afetado e, em seguida, expanda a seção de exibição de discos:Figura 2: exibição do grupo de discos do vSAN > Aqui você pode verificar se um disco é detectado >como:




Exibição do gerenciamento de disco do vSAN Exibição do grupo de discos do vSAN



 
Unhealthy
Desmontado
0 Capacidade
Falha permanente do disco Disco inativo Disco
ausente


Além disso, verifique se há alarmes relacionados ao disco disparados na seção vSAN Skyline Health: 
 
Inventário > Host e clusters Monitorar o cluster > do vSAN Integridade do horizonte do > vSAN > Imagem 3:>>

Visualização
Visualização da integridade do horizonte
da integridade do horizonte Aqui, você pode verificar se algum dos alarmes a seguir foi acionado:
 
Iminente falha permanente do disco, os dados estão sendo evacuados (estado de integridade - amarelo).
Falha permanente do disco iminente; falha na evacuação de dados devido a recursos insuficientes (estado de integridade - vermelho).
Falha permanente do disco iminente, falha na evacuação de dados devido a objetos inacessíveis (estado de integridade - vermelho).
Falha permanente do disco iminente, evacuação de dados concluída (estado de integridade - amarelo)
 
Além disso, você pode verificar o status do disco na lista de dispositivos de armazenamento do host afetado:
 
Inventário > Host e clusters > Cluster > do vSAN afetado pelo host > do ESXi do vSAN Configurar > dispositivos de armazenamento de armazenamento >Figura 4:

Visualização
Visualização de dispositivos de armazenamento do host
de dispositivos de armazenamento do host Aqui, você pode verificar se o status de um disco é:
 
0 disco ausente
de capacidade
disco desmontado

Verifique se há uma ressincronização acontecendo: 
 
Inventário > Host e clusters > Cluster vSAN > Monitor > vSAN > Resincronizando objetos:Figura 5:

Exibição Ressincronizando objetos
Exibição Ressincronizando objetos
Nota: A ressincronização pode indicar que os dados estão sendo evacuados de um disco ou grupo de discos afetado. É necessária uma investigação adicional para determinar se o disco afetado está pronto para ser removido ou substituído.

 
Verifique o status dos objetos vSAN:
 
Inventário > Host e clusters > Cluster > vSAN Monitorar > dados de integridade do horizonte do vSAN Integridade do objeto vSAN Figura 6: exibição da integridade > do > objeto vSAN >


Exibição de integridade de objeto do vSAN
Nota: É importante verificar se não há objetos inacessíveis. Objeto inacessível significa que "todas as cópias do objeto estão ausentes". Se você remover ou substituir um disco que possa causar DL.

 
A próxima etapa é coletar mais informações sobre o problema na CLI e verificar os logs:Checking for vSAN Physical Disk status from CLI:Connect over SSH to the affected host e executar os seguintes comandos:




 
vdq -qH
Verifique o parâmetro "IsPDL" (perda permanente de dispositivo). Se for igual a 1, o disco será perdido.
 
Exemplo:
 
DiskResults:
 DiskResult[0]:
 Name: naa.600508b1001c4b820b4d80f9f8acfa95
 VSANUUID: 5294bbd8-67c4-c545-3952-7711e365f7fa
 State: In-use for VSAN
 ChecksumSupport: 0
 Reason: Non-local disk
 IsSSD?: 0
IsCapacityFlash?: 0
 IsPDL?: 0
 <<truncated>>
 DiskResult[18]:
 Name:
 VSANUUID: 5227c17e-ec64-de76-c10e-c272102beba7
 State: In-use for VSAN
 ChecksumSupport: 0
 Reason: None
 IsSSD?: 0
IsCapacityFlash?: 0
 IsPDL?: 1
 
vdq -iH
Verifique se há um disco ausente no grupo de discos.
 
Exemplo:
 
Mappings:
DiskMapping[0]:
SSD: naa.58ce38ee2016ffe5
MD: naa.5002538a4819e3e0
 
DiskMapping[2]:
SSD: naa.58ce38ee2016fe55
MD: naa.5002538a48199ca0
MD: naa.5002538a48199e20
MD: naa.5002538a48199e00
 
esxcli vsan storage list
Verifique o parâmetro "In CMMDS". Se falso, a comunicação será perdida no disco.
 
Exemplo:
 
Device: Unknown
Display Name: Unknown
Is SSD: false
VSAN UUID: 529cadbc-acd1-b588-8643-68336d5512d6
VSAN Disk Group UUID:
VSAN Disk Group Name:
Used by this host: false
In CMMDS: false
On-disk format version: <Unknown>
Deduplication: false
Compression: false
Checksum:
Checksum OK: false
Is Capacity Tier: false
 
for i in `esxcli  storage core device list | grep ^naa` ; do echo $i; esxcli storage core device smart get -d $i; done.
Verifique se há erros de leitura/gravação com o comando smart get.
 
Exemplo:
 
naa.55cd2e404c1f35a1
Parameter                   Value  Threshold  Worst  Raw
--------------------------  -----  ---------  -----  ---
Health Status               OK     N/A        N/A    N/A
Media Wearout Indicator     100    0          100    86
Read Error Count            130    39         130    133
Power-on Hours              100    0          100    110
Power Cycle Count           100    0          100    106
Drive Temperature           100    0          100    26
Uncorrectable Sector Count  100    0          100    0
naa.55cd2e404c1f35a5
Parameter                   Value  Threshold  Worst  Raw
--------------------------  -----  ---------  -----  ---
Health Status               OK     N/A        N/A    N/A
Media Wearout Indicator     100    0          100    10
Read Error Count            130    39         130    53
Power-on Hours              100    0          100    110
Power Cycle Count           100    0          100    106
Drive Temperature           100    0          100    27
Uncorrectable Sector Count  100    0          100    0
 
esxcli vsan storage list | grep "VSAN Disk Group UUID:" | sort | uniq -c
Verifique se há grupos de discos disponíveis.
 
Exemplo:
 
      2    VSAN Disk Group UUID: 5203424c-ee56-497d-75d1-fcf73ae997cb
      2    VSAN Disk Group UUID: 52af8e5c-77d1-b552-3310-ec5fef09edf4
 
while true;do echo " ****************************************** "; echo "" > /tmp/resyncStats.txt ;cmmds-tool find -t DOM_OBJECT -f json |grep uuid |awk -F \" '{print $4}' |while read i;do pendingResync=$(cmmds-tool  find -t DOM_OBJECT -f json -u $i|grep -o "\"bytesToSync\": [0-9]*,"|awk -F " |," '{sum+=$2} END{print sum / 1024 / 1024 / 1024;}');if [ ${#pendingResync} -ne 1 ]; then echo "$i: $pendingResync GiB";fi;done |tee -a /tmp/resyncStats.txt;total=$(cat /tmp/resyncStats.txt |awk '{sum+=$2} END{print sum}');echo "Total: $total GiB" |tee -aa /tmp/resyncStats.txt;total=$(cat /tmp/resyncStats.txt  |grep Total);totalObj=$(cat /tmp/resyncStats.txt|grep -vE " 0 GiB|Total"|wc -l);echo "`date +%Y-%m-%dT%H:%M:%SZ` $total ($totalObj objects)" >> /tmp/totalHistory.txt; echo `date `; sleep 60; done
Verifique se há operações de ressincronização em andamento ou travadas.
 
Exemplo:
 
Total: 0 GiB
Mon Feb 13 17:32:06 UTC 2023

Pressione Ctrl+C para interromper o comando.
 
cmmds-tool find -f python | grep CONFIG_STATUS -B 4 -A 6 | grep 'uuid\|content' | grep -o 'state\\\":\ [0-9]*' | sort | uniq -c
Verifique o estado dos componentes.
 
Íntegro -- estado 7
Inacessível -- estado 13
Ausente ou degradado -- estado 15
 
Exemplo:
 
    425 state\": 7
 
Como identificar onde a SSD ou a unidade de disco rígido com falha está localizada pela CLI:
 
Listar todos os dispositivos disponíveis:
esxcli storage core device list | grep "naa" | awk '{print $1}' | grep "naa"

Exemplo:
 
naa.5000c500852df8d3
naa.55cd2e404c1f35a1
naa.55cd2e404c1f35a5
naa.5000c500852dd5e7

Verifique o local usando cada disco NAA na lista:
esxcli storage core device physical get -d
 
Exemplo:
 
esxcli storage core device physical get -d naa.5000c500852df8d3
esxcli storage core device physical get -d naa.55cd2e404c1f35a1
esxcli storage core device physical get -d naa.55cd2e404c1f35a5
esxcli storage core device physical get -d naa.5000c500852dd5e7
 
   Physical Location: enclosure 65535 slot 0
   Physical Location: enclosure 65535 slot 1
   Physical Location: enclosure 65535 slot 2
   Physical Location: enclosure 65535 slot 3

Como identificar o disco rígido ou SSD com falha se o nome do dispositivo estiver faltando:

É possível que o disco com falha não seja detectado e não seja possível identificá-lo usando o NAA correspondente. Nesse cenário, é necessário localizar todos os discos, e o que não está fisicamente localizado seria o que falhou.

Aqui está um script que pode ser usado para executar a tarefa um pouco mais rápido:
echo "=============Physical disks placement=============="
echo ""
esxcli storage core device list | grep "naa" | awk '{print $1}' | grep "naa" | while read in; do
echo "$in"
esxcli storage core device physical get -d "$in"
sleep 1
echo "===================================================="
done

Registros relevantes do vSAN para problemas relacionados a armazenamento:
 
/var/log/vmkernel.log
Problemas de leitura e gravação em discos do vSAN, heartbeats do host do vSAN, PDLs, códigos de detecção SCSI e solicitações de E/S (leituras/gravações) e informações de associação do cluster.
 
Exemplo:
 
2021-06-22T12:02:08.408Z cpu30:1001397101)ScsiDeviceIO: PsaScsiDeviceTimeoutHandlerFn:12834: TaskMgmt op to cancel IO succeeded for device naa.55cd2e404b7736d0 and the IO did not complete. WorldId 0, Cmd 0x28, CmdSN = 0x428.Cancelling of IO will be
2021-06-22T12:02:08.408Z cpu30:1001397101)retried.

/var/log/vobd.log
Relata a integridade do disco, os PDLs (discos permanentes perdidos do dispositivo), a latência do disco e informa quando um host entra e sai do modo de manutenção.
 
Exemplo:
 
2022-05-31T11:42:46.065Z: [vSANCorrelator] 10605891965954us: [vob.vsan.lsom.devicerepair] vSAN device 521a74ce-c980-c16c-ff3d-38a036233daf is being repaired due to I/O failures, and will be out of service until the repair is complete. If the device is part of a dedup disk group, the entire disk group will be out of service until the repair is complete.
2022-05-31T11:42:46.065Z: [vSANCorrelator] 10606062774178us: [esx.problem.vob.vsan.lsom.devicerepair] Device 521a74ce-c980-c16c-ff3d-38a036233daf is in offline state and is getting repaired

/var/log/vsandevicemonitord.log ajuda a determinar se o disco foi marcado como não íntegro devido ao congestionamento excessivo de logs ou latências de E/S
.
 
Exemplo:
 
INFO vsandevicemonitord WARNING - WRITE Average Latency on VSAN device naa.50000xxxxxxxx has exceeded threshold value 2000000 us 2 times.
INFO vsandevicemonitord Tier 2 (naa.50000xxxxxxxx) as unhealthy

Article Properties


Affected Product

VMware ESXi 7.x, VMware VSAN

Product

VMware, VMware ESXi 6.7.X

Last Published Date

12 Feb 2024

Version

3

Article Type