ECS: Rullegardinlisten Avansert overvåking mangler en node
Summary: Avansert overvåking – ytelse for datatilgang – rullegardinlisten Noder viser ikke en node.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Rullegardinlisten Avansert overvåking - datatilgangsytelse - av noder viser ikke en node.
I dette eksemplet mangler node 3 i rullegardinlisten:

Cause
ECS er nylig installert. Programmet sender ikke I/O til noder som mangler i rullegardinlisten Avansert overvåking – datatilgangsytelse – av noder .
Resolution
- Kontroller at det ikke finnes S3 eller CAS I/O til node(r):
kpi -cas -start '7 days ago' kpi -start '7 days ago'
I dette eksemplet er det ingen S3 I/O til denne ECS og ingen CAS I/O til r1n3:
admin@node1:~> kpi -start '7 days ago'
kpi v3.4.2 (svc_tools v2.24.0-rc) Started 2025-11-12 01:05:34
Time range: 2025-11-05 01:05:34 - 2025-11-12 01:05:34
All Requests 500 Errors
Node GETs PUTs POSTs DELETEs HEADs Total GETs PUTs POSTs DELETEs HEADs Total % Fail
r1n1 0 0 0 0 0 0 0 0 0 0 0 0 0.00
r1n2 0 0 0 0 0 0 0 0 0 0 0 0 0.00
r1n3 0 0 0 0 0 0 0 0 0 0 0 0 0.00
r1n4 0 0 0 0 0 0 0 0 0 0 0 0 0.00
r1n5 0 0 0 0 0 0 0 0 0 0 0 0 0.00
Totals 0 0 0 0 0 0 0 0 0 0 0 0 0.00
Req Error %: 0.00 0.00 0.00 0.00 0.00 0.00
--------------------------------------------------------------------------------------------------------------------
Non-200 Response codes
--------------------------------------------------------------------------------------------------------------------
Resp Code Description GETs PUTs POSTs DELETEs HEADs Total % Total Reqs
-----------------------------------------------------------------------------------------------
500 Internal Server Error 0 0 0 0 0 0 0.00
admin@node1:~> kpi -cas -start '7 days ago'
kpi v3.4.2 (svc_tools v2.26.0) Started 2025-11-10 02:44:58
Time range: 2025-11-03 02:44:58 - 2025-11-10 02:44:58
All Requests -10005 Errors
Node READs WRITEs DELETEs EXIST_CHECKs Total READs WRITEs DELETEs EXIST_CHECKs Total % Fail
r1n1 0 12058 0 0 12058 0 0 0 0 0 0.00
r1n2 608 0 0 0 608 0 0 0 0 0 0.00
r1n3 0 0 0 0 0 0 0 0 0 0 0.00
r1n4 608 0 0 0 608 0 0 0 0 0 0.00
r1n5 0 12058 0 0 12058 0 0 0 0 0 0.00
Totals 1216 24116 0 0 25332 0 0 0 0 0 0.00
Req Error %: 0.00 0.00 0.00 0.00 0.00
--------------------------------------------------------------------------------------------------------------------
Non-200 Response codes
--------------------------------------------------------------------------------------------------------------------
Resp Code Description READs WRITEs DELETEs Total % Total Reqs
-----------------------------------------------------------------------
-10005 FP_SERVER_ERR 0 0 0 0 0.00
- Hvis det ikke mangler I/O til node(r) fra rullegardinlisten Avansert overvåking – datatilgangsytelse – av noder, er dette normal atferd.
- Når I/O er mottatt på node(r) som mangler fra rullegardinlisten, skal node(r) vises på rullegardinlisten.