Dell Unity: Unity All-Flash Array (AFA) is reporting “15b4000 [WARN] System” messages with lane errors (“Lane 0 Error”). (Dell Correctable)
Summary: The user reports seeing repeated warning messages in the event log on a Dell Unity All-Flash array.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
All-Flash platform supported by the 4.2.x OE release
Warning events are reported for one or more lanes as follows:
A 10/06/17 04:42:03.385 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 0 Error "
A 10/06/17 04:42:03.397 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 1 Error "
A 10/06/17 04:42:03.409 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 2 Error "
A 10/06/17 04:42:03.420 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 3 Error "
A 10/06/17 04:42:03.432 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 4 Error "
A 10/06/17 04:42:03.443 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 5 Error "
A 10/06/17 04:42:03.455 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 6 Error "
A 10/06/17 04:42:03.467 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 7 Error "
Unisphere shows one of the SPs faulted:
The array may also dialhome with code: neo14:6044c
Warning events are reported for one or more lanes as follows:
A 10/06/17 04:42:03.385 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 0 Error "
A 10/06/17 04:42:03.397 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 1 Error "
A 10/06/17 04:42:03.409 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 2 Error "
A 10/06/17 04:42:03.420 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 3 Error "
A 10/06/17 04:42:03.432 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 4 Error "
A 10/06/17 04:42:03.443 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 5 Error "
A 10/06/17 04:42:03.455 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 6 Error "
A 10/06/17 04:42:03.467 HwErrMon 15b4000 [WARN] System: HwErrMon Warning: B:0x0,D:0x3,F:0x0,O:0x258 Value:0xFF "Lane 7 Error "
Unisphere shows one of the SPs faulted:
The array may also dialhome with code: neo14:6044c
Cause
A correctable event occurred within the hardware located on the Storage Processor (SP) supporting the inter-SP connection known as the CMI (Common Management Interface). This event may be reported for a single lane within the CMI but all lanes are reported in the log every time.
Resolution
These messages can safely be ignored. There is no need to replace hardware at this time. PCIe correctable errors are corrected as they occur. The error threshold allows for no more than 100 errors per lane within a 24 hour period. The warning messages are generally expected in low numbers and must be tolerated. They do not warrant hardware replacement, and any impact to the performance of the system is negligible. The correctable error warning messages can occur with any hardware, even new replacement hardware. This is why hardware replacement is not recommended unless the correctable error threshold is exceeded.
This issue has been fixed in Dell EMC Unity Operating Environment (OE) version 4.3.1 and later. The fix increases the error threshold to 1000 error per lane within a 24 hour period.
Reboot the SP showing as faulted and upgrade to Unity OE 4.3.1 or later to obtain the fix.
This issue has been fixed in Dell EMC Unity Operating Environment (OE) version 4.3.1 and later. The fix increases the error threshold to 1000 error per lane within a 24 hour period.
Reboot the SP showing as faulted and upgrade to Unity OE 4.3.1 or later to obtain the fix.
Additional Information
Please note that an issue exists where one or both SPs may show as faulted in the GUI even though they are seen as normal from CLI. As described above, this should have no impact on the system, unless the SP is truly faulted.
Affected Products
Dell EMC Unity Family |Dell EMC Unity All FlashProducts