MFE SCF: EMCP020E EXTRANEOUS DATA IN COMMAND returned when Thin Monitoring parameter ACTION=MESSAGE(MESSAGE) coded.

Resumen: Incorrect verification of the MESSAGE parameter with PARM_VERIFY=YES

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

When the PARM_VERIFY=YES parameter is specified in the ResourcePak Base initialization file, the incorrect EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: ")"  message is displayed. 
Example:
SCF0301I SCF.THN.03.LIST = ACTION=MESSAGE(MESSAGE)
SCF0313I SCF.THN.03.LIST=ACTION=MESSAGE(MESSAGE)
EMCP010E *
EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: )
SCF0301I SCF.THN.03.LIST = FREQUENCY=REPEAT
SCF0301I SCF.THN.04.LIST = PERCENT=(99,100)
SCF0301I SCF.THN.04.LIST = DURATION=60
SCF0301I SCF.THN.04.LIST = ACTION=MESSAGE(MESSAGE)
SCF0313I SCF.THN.04.LIST=ACTION=MESSAGE(MESSAGE)
EMCP010E *
EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: )
SCF0301I SCF.THN.04.LIST = FREQUENCY=REPEAT                      

Causa

This is due to a software issue.

Resolución

Permanent Fix:
  • For Mainframe Enablers 8.5, PTF SF85111 has been developed to correct the issue. It is available to download from Dell Online Support.
  • For Mainframe Enablers 8.4, PTF SF84158 has been developed to correct the issue. It is available to download from Dell Online Support.

Información adicional

EMCP020E
EXTRANEOUS DATA IN COMMAND; FOUND: value
Cause
While parsing the input data stream, a syntax error was detected, and extraneous data was found.
Action
Correct the input data stream.

PTF Cover Note:
 
++PTF(SF85111) REWORK(2022038) .                               
++VER(Z038) FMID(SSCF850)                                     
      PRE(                                                    
          SF85002 SF85042                                     
          )                                                    
   /*                                                         
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):                                     
* ------------------------------------------------------------
* USERS AFFECTED: Users of the THN Monitor                    
* PROBLEM DESCRIPTION: Incorrect verification of the MESSAGE  
*                      parameter with PARM_VERIFY=YES         
* DESCRIPTION DETAIL:                                         
*                                                             
* When the PARM_VERIFY=YES parameter is specified in the SCF  
* initialization file, the incorrect                          
* EMCP020E EXTRANEOUS DATA IN COMMAND; FOUND: )               
* message is displayed.                                       
*                                                             
* PROBLEM RESOLUTION:                                         
*                                                             
* The code has been updated to correctly verify syntax of the 
* MESSAGE parameter.                                          
*                                                             
* MODULES: ESFINI                                             
*          SCFLIND                                            
*                                                             
* ------------------------------------------------------------
* SF85111 7 Feb 2022 15:15:32                                 
* ------------------------------------------------------------

Productos afectados

Mainframe Enablers
Propiedades del artículo
Número del artículo: 000196982
Tipo de artículo: Solution
Última modificación: 16 jun 2023
Versión:  5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.